2006
DOI: 10.1590/s0100-46702006000200001
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of Cd and Pb in antibiotics used in sugar-cane fermentation process by GFAAS

Abstract: A method has been developed for the simultaneous determination of Cd and Pb in antibiotics used in sugar-cane fermentation by GFAAS. The integrated platform of transversely heated graphite atomizer was treated with tungsten to form a coating of tungsten carbide. Six samples of commercial solid antibiotics were analyzed by injecting 20 µL of digested samples into the pretreated graphite platform with co-injection of 5 µL of 1000 mg L-1 Pd as chemical modifier. Samples were mineralized in a closed-vessel microwa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2011
2011
2013
2013

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 14 publications
0
3
0
Order By: Relevance
“…This is a suitable and widely used technique for determining trace elements due to its high selectivity, sensitivity, and ability to directly determine several analytes in different samples (AMORIM FILHO et al, 2006).…”
Section: Graphite Furnace Atomic Absorption Spectrometry (Gf Aas)mentioning
confidence: 99%
“…This is a suitable and widely used technique for determining trace elements due to its high selectivity, sensitivity, and ability to directly determine several analytes in different samples (AMORIM FILHO et al, 2006).…”
Section: Graphite Furnace Atomic Absorption Spectrometry (Gf Aas)mentioning
confidence: 99%
“…Since these samples are completely soluble in water, they were diluted 1:200 (w/v) in deionized water before analysis. A fertilizer reference material (NIST 120c -Phosphate Rock, National Institute of Standards and Technology, Gaithersburg, MD, USA) was digested in a closed microwave system with pressure and temperature control according to a procedure described in the literature (12).…”
Section: Sample Preparationmentioning
confidence: 99%
“…Number of multi-element Atomic Absorption spectrometers has been developed [4,5]. Presently, the most widely used instrument is a line source simultaneous spectrometer, equipped with transversely heated graphite atomizer, THGA with integrated platform, Zeeman Effect background corrector and solid-state detector [6][7][8][9][10][11][12][13][14][15][16][17][18][19][20]. However, multi-element determinations carried out by SIMAAS need the adoption of compromised conditions, which can affect the sensitivity and the precision of analytical results [21,22].…”
Section: Introductionmentioning
confidence: 99%