2012
DOI: 10.1590/s0100-40422012000700029
|View full text |Cite
|
Sign up to set email alerts
|

Determinação simultânea de ácido ascórbico e ácido acetilsalicílico usando análise por injeção em fluxo com detecção amperométrica pulsada

Abstract: Recebido em 22/11/11; aceito em 28/1/12; publicado na web em 30/4/12 SIMULTANEOUS DETERMINATION OF ASCORBIC ACID AND ACETYLSALICYLIC ACID USING FLOW INJECTION ANALYSIS WITH MULTIPLE PULSE AMPEROMETRIC DETECTION. A simple flow system with multiple pulse amperometric detection using a single working electrode is proposed for simultaneous determination of ascorbic (AA) and acetylsalicylic (AAS) acids in pharmaceutical formulations. The procedure is based on application of two potential pulses: 0.90 V/50 ms: oxida… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
1
0
4

Year Published

2013
2013
2018
2018

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 16 publications
(18 reference statements)
0
1
0
4
Order By: Relevance
“…ASA exhibits anodic peak currents from + 1.5 V up to 1.8 V and an abrupt increase up to +2.3 V (studied interval). The obtained irreversible oxidation of these compounds over cathodically pre‐treated BDDE in acid media has already been observed using DPV and MPA detection . The oxidation mechanisms on carbon electrodes proposed in literature involve a transfer of 2‐electron and 2‐proton for PA , 4‐electron and 4‐proton for CA , 1‐electron and 1‐proton for SA and 2‐electron and 1‐proton for ASA .…”
Section: Resultsmentioning
confidence: 99%
“…ASA exhibits anodic peak currents from + 1.5 V up to 1.8 V and an abrupt increase up to +2.3 V (studied interval). The obtained irreversible oxidation of these compounds over cathodically pre‐treated BDDE in acid media has already been observed using DPV and MPA detection . The oxidation mechanisms on carbon electrodes proposed in literature involve a transfer of 2‐electron and 2‐proton for PA , 4‐electron and 4‐proton for CA , 1‐electron and 1‐proton for SA and 2‐electron and 1‐proton for ASA .…”
Section: Resultsmentioning
confidence: 99%
“…18 Diariamente, antes do início das análises, apenas a limpeza catódica era efetivamente realizada. 18,[28][29][30] A limpeza anódica somente é necessária quando ocorre uma contaminação mais drástica do eletrodo de BDD, o que não ocorre no procedimento proposto de determinação de HQ. Eletrodos comerciais de ouro (0,283 cm 2 ; Metrohm) e carbono vítreo (0,283 cm 2 ; Metrohm) foram usados em estudos preliminares.…”
Section: Medidas Eletroquímicasunclassified
“…-em E2, ambas as espécies são oxidadas ou reduzidas. MEDEIROS et al, 2010;MIRANDA et al, 2012;SILVA et al, 2011)] e acoplada a sistemas BIA (BIA-MPA) (GIMENES et al, 2013(GIMENES et al, , 2014PEREIRA et al, 2013PEREIRA et al, , 2014TORMIN et al, 2012).…”
Section: Amperometriaunclassified