2008
DOI: 10.1590/s0100-40422008000100017
|View full text |Cite
|
Sign up to set email alerts
|

Determinação de herbicidas usados no cultivo de arroz irrigado na região sul do estado de Santa Catarina através da SPME-GC-ECD

Abstract: Recebido em 21/12/06; aceito em 21/6/07; publicado na web em 19/12/07 DETERMINATION OF HERBICIDES USED IN IRRIGATED RICE CULTIVATION IN THE SOUTH OF SANTA CATARINA USING SPME-GC-ECD. Evaluation of the pollution by the herbicides alachlor, propanil and atrazine in water samples from four rivers in the cities of Turvo and Meleiro, south of Santa Catarina State, was made using the SPME-GC-ECD method. The proposed method was optimized and validated. The correlation coefficients were higher than 0.997 and linear ra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0
4

Year Published

2010
2010
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(10 citation statements)
references
References 14 publications
0
6
0
4
Order By: Relevance
“…Nos rios que tem produção de arroz irrigado em suas bacias hidrográficas, a proximidade das lavouras em relação aos cursos d'água e o volume de água utilizado na irrigação são aspectos importantes que, associados à precipitação pluvial, favorecem o transporte de agrotóxicos das lavouras de arroz irrigado para os mananciais hídricos superficiais (COSTA et al, 2008;MARCHESAN et al, 2007 , para 2,4-D, e 20μg L -1 , para propanil, como padrão de potabilidade. Para a União Europeia, a concentração máxima é 0,1μg L -1 para cada agrotóxico e 0,5μg L -1 para o total de agrotóxicos em águas destinadas ao consumo humano, independente de sua toxicidade (COUNCIL DIRECTIVE, 1980).…”
Section: Introductionunclassified
“…Nos rios que tem produção de arroz irrigado em suas bacias hidrográficas, a proximidade das lavouras em relação aos cursos d'água e o volume de água utilizado na irrigação são aspectos importantes que, associados à precipitação pluvial, favorecem o transporte de agrotóxicos das lavouras de arroz irrigado para os mananciais hídricos superficiais (COSTA et al, 2008;MARCHESAN et al, 2007 , para 2,4-D, e 20μg L -1 , para propanil, como padrão de potabilidade. Para a União Europeia, a concentração máxima é 0,1μg L -1 para cada agrotóxico e 0,5μg L -1 para o total de agrotóxicos em águas destinadas ao consumo humano, independente de sua toxicidade (COUNCIL DIRECTIVE, 1980).…”
Section: Introductionunclassified
“…The authors used the same SPME fibre as that employed in this work. On the other hand, Costa et al used polyacrylate (PA 85 µm) fibre and obtained better results in comparison with the ones found when PDMS (75 µm) and CW/DVB (65 µm) fibres were employed. They obtained recoveries of 75.4–116.9%, 76.1–106.7% and 96.2–103.9% for alachlor, atrazine and propanil herbicides, respectively, in rice analysis.…”
Section: Resultsmentioning
confidence: 97%
“…The authors used the same SPME fibre as that employed in this work. On the other hand, Costa et al 18 used polyacrylate (PA 85 μm) fibre and obtained better results in comparison with the ones found when PDMS (75 μm) wileyonlinelibrary.com/journal/ps Figure 6. Correlation curve obtained from spiked contents and contents of methyl parathion insecticide found in fortified rice samples by HS-SPME-GC/MS (n = 7).…”
Section: Analytical Methods Optimisationmentioning
confidence: 92%
“…A preocupação social acerca dos níveis dos herbicidas no ambiente e a constante tendência observada na legislação para reduzir seus níveis máximos permitidos em uma variedade de matrizes estão aumentando o número de amostras que precisam ser monitoradas e a necessidade de sua determinação precisa a níveis cada vez mais baixos (BOUAD et al, 2001). A determinação em matrizes ambientais, entre elas o solo, exige o uso de métodos de preparação seletivos e que envolvam etapas de extração, limpeza e pré-concentração anteriores à determinação cromatográfica (COSTA et al, 2008). Na etapa de pré-concentração, a Extração em Fase Sólida (SPE) é usualmente empregada com o propósito de isolar um ou mais analitos presentes em uma matriz complexa para posterior análise por intermédio do uso de um método instrumental (LANÇAS, 2004).…”
Section: Introductionunclassified