2003
DOI: 10.1590/s0100-40422003000400004
|View full text |Cite
|
Sign up to set email alerts
|

Emprego de padrão único para a construção de curvas analíticas em sistema de análise por injeção em fluxo associado à espectrofotometria em fase sólida

Abstract: Recebido em 15/5/02; aceito em 13/11/02 EMPLOYMENT OF A SINGLE STANDARD SOLUTION FOR ANALYTICAL CURVES IN FLOW INJECTION ANALYSIS SYSTEM COUPLED TO SOLID PHASE SPECTROPHOTOMETRY. In this work two procedures were proposed for analytical curves construction using a single standard solution employing a flow injection system with solid phase spectrophotometric detection (FI-SPS). A flow cell contends the chromogenic reagent 1-(2-tiazolylazo)-2-naphtol was positioned on the optical path. The first procedure was bas… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2005
2005
2012
2012

Publication Types

Select...
2
1
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 13 publications
0
2
0
Order By: Relevance
“…The valve activation and data acquisition were controlled by PC, as earlier described. 12 The assays with the residual solution of the Thiamethoxam ® were carried out by sonicating 5 mL of 100 mg L -1 of the herbicide solution in interval range from 10 to 60 min. After sonication, the chloride generated by sonochemical effect and the pH were measured.…”
Section: Methodsmentioning
confidence: 99%
“…The valve activation and data acquisition were controlled by PC, as earlier described. 12 The assays with the residual solution of the Thiamethoxam ® were carried out by sonicating 5 mL of 100 mg L -1 of the herbicide solution in interval range from 10 to 60 min. After sonication, the chloride generated by sonochemical effect and the pH were measured.…”
Section: Methodsmentioning
confidence: 99%
“…[10][11][12] Multicommuted flow analysis process affords facilities to design active flow setup constituted by solenoid valves, which have been assembled to work as an independent commutator unit, thus allowing facilities to handle sample and reagent solutions controlled by microcomputer. [8][9][10][11]13,14 Zinc is present in all living cells as a constituent of several molecules involved in proteins, lipids and carbohydrates metabolism, as well as several enzymes. 15,16 In this sense, zinc is considered as an essential element for all animals, including humans.…”
Section: Introductionmentioning
confidence: 99%