2002
DOI: 10.1590/s0100-40422002000200020
|View full text |Cite
|
Sign up to set email alerts
|

Imunossensor amperométrico

Abstract: Recebido em 21/12/00; aceito em 17/10/01 AMPEROMETRIC IMMUNOSENSOR. The reaction between antigen and antibody has been widely used in many strategies for the development of analytical methodology, due to its high specificity. The immuno-reaction has been successfully employed for the biosensor development. A focus on biosensor based on immunoassay coupled to amperometric transducer is presented.Keywords: immunosensor; immunoanalysis; amperometric. INTRODUÇÃOBiossensor é um dispositivo no qual o material de ori… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0
4

Year Published

2003
2003
2018
2018

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 42 publications
0
4
0
4
Order By: Relevance
“…Recently, mimetic molecules have also been suggested, instead of enzymes or antibodies. 127,128 The interaction between the antibody (A b ) and antigen (A g ) is characterised by its affinity constant, K, defined by the equilibrium concentrations of the A b -A g complex, the free analyte and the free antibody binding sites (where…”
Section: Amperometric Biosensorsmentioning
confidence: 99%
See 1 more Smart Citation
“…Recently, mimetic molecules have also been suggested, instead of enzymes or antibodies. 127,128 The interaction between the antibody (A b ) and antigen (A g ) is characterised by its affinity constant, K, defined by the equilibrium concentrations of the A b -A g complex, the free analyte and the free antibody binding sites (where…”
Section: Amperometric Biosensorsmentioning
confidence: 99%
“…The final stage of this immunoasssay format is in fact the quantitative detection of the label. 132 Yamanaka and co-workers has been contributed to the field of immunoassay development in Brazil, 128,131 where investigations of biosensors based on the reaction between antigen and antibody coupled to an amperometric transducer are currently in progress. An example 131 of the monitoring of the peroxide (POD) labeled antigen complexed with Ab immobilized onto the electrode surface is shown in Figure 3.…”
Section: Amperometric Biosensorsmentioning
confidence: 99%
“…Imunossensores amperométricos automatizados e, na maioria dos casos, operando em FIA, têm sido desenvolvidos para análise de poluentes de baixo peso molecular 165,166 , e uma nova categoria de sistemas analíticos foi descrita pela primeira vez em 1992, dando origem aos sistemas de imunoanálises por injeção em fluxo ("flow-injection immunoanalysis systems", FIIA) 10 . Em geral, os biossensores dispensam o tratamento da amostra, principalmente se esta for líquida ou pastosa, sendo ainda muito mais rápidos e sensíveis que os métodos convencionais.…”
Section: Avanços E Perspectivasunclassified
“…Enquanto nos biossensores com enzima são monitoradas as concentrações de substratos, produtos ou mediadores, nos imunossensores [7][8][9] , que são dispositivos analíticos, baseados nos princípios de imunoensaios heterogêneos e nos eventos físico-químicos, são resultantes da reação de afinidade antígeno-anticorpo (Ag-Ac).…”
Section: Introductionunclassified
“…Essa interação é mantida por forças fracas, como forças iônicas, ligações de hidrogênio, forças eletrodinâmicas (van der Waals) e hidrofóbicas, garantindo o fenômeno da especificidade antígeno-anticorpo. Também podem ocorrer reações não-específicas (reações cruzadas) de outros anticorpos que competem pela ligação com o antígeno 8,10 , como, por ex., ligação com o antígeno 8,10 .Ac + Ag ↔ Ag-Ac (1) A formação do complexo (Ag-Ac) pode ser monitorada diretamente (sem a presença de marcador) ou pelo método indireto (com a presença de marcadores). Tanto o antígeno quanto o anticorpo podem ser marcados (conjugados) e as enzimas, atualmente, são os marcadores mais empregados em imunoensaios.…”
unclassified