1999
DOI: 10.1590/s0100-40421999000500006
|View full text |Cite
|
Sign up to set email alerts
|

Utilização de eletrodos potenciométricos de amálgama em estudos de complexação de substâncias húmicas

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
1

Year Published

2001
2001
2013
2013

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 0 publications
0
6
0
1
Order By: Relevance
“…For complexometric titrations both pH-meters were used; one of them was used for monitoring the pH, that was kept at pH 6.00 ± 0.05 with the aid of the above mentionated combination glass electrode. The other pHmeter was used with an ion selective electrode (ISE-Orion 9429) for Cu(II), or with a hanging mercury drop electrode (HMDE -Metrohm 6.0335-000) filled with Pb, Cd or Zn amalgams, prepared according previous papers 8,9 , and using a double junction Ag/AgCl reference electrode (Mettler 373-90WTEISE-S7/105).…”
Section: Apparatus and Reagentsmentioning
confidence: 99%
See 2 more Smart Citations
“…For complexometric titrations both pH-meters were used; one of them was used for monitoring the pH, that was kept at pH 6.00 ± 0.05 with the aid of the above mentionated combination glass electrode. The other pHmeter was used with an ion selective electrode (ISE-Orion 9429) for Cu(II), or with a hanging mercury drop electrode (HMDE -Metrohm 6.0335-000) filled with Pb, Cd or Zn amalgams, prepared according previous papers 8,9 , and using a double junction Ag/AgCl reference electrode (Mettler 373-90WTEISE-S7/105).…”
Section: Apparatus and Reagentsmentioning
confidence: 99%
“…The preparation of the standard solutions of metallic cations and sodium hidroxide solutions has already been described in the literature 9,[16][17][18] .…”
Section: Apparatus and Reagentsmentioning
confidence: 99%
See 1 more Smart Citation
“…No caso das titulações de complexação, os tratamentos de dados para calibração do eletrodo íon seletivo a Cu(II), cálculo de concentração de Cu(II) livre, [Cu(II)], e complexado, [CuL], também podem ser encontrados em publicações anteriores 11,15,16 . No presente trabalho adotou-se que os dados experimentais de complexação podem ser descritos pela equação da isoterma de Langmuir, que assume que os complexos formados têm estequiometria 1:1 e que o experimento é conduzido em força iônica e temperatura constantes, de modo que a carga elétrica sobre a superfície mantém-se constante, assim como sua conformação espacial.…”
Section: Métodos De Cálculounclassified
“…A Radelkis OP 936 microburette supporting a 10-mL glass syringe was used to dispense copper titrant. The dissolved oxygen was previously removed by bubbling ultrapure nitrogen (99.99%) through the solution for 15 min and a nitrogen atmosphere was maintained above the solution during the experiments [12]. Almost all experiments were performed at 25.0±0.1°C and ionic strength adjustment of 0.1 mol L -1 NaNO 3 .…”
Section: Ion Selective Electrode (Ise) Proceduresmentioning
confidence: 99%