1999
DOI: 10.1590/s0100-40421999000100023
|View full text |Cite
|
Sign up to set email alerts
|

Classificação e definição dos métodos de análises em fluxo (Recomendações - IUPAC 1994)

Abstract: Recebido em 23/4/98; aceito em 7/5/98 CLASSIFICATION AND DEFINITION OF ANALYTICAL METHODS BASED ON FLOWINGMEDIA. The aim of this report is to classify analytical methods based on flowing media and to define (standardize) terminology. After the classification and a discussion of terms describing the systems and component parts, a section is devoted to terms describing the performance of flow systems. The list of terms included is restricted to the most relevant ones; especially "self-explanatory" terms are left… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
4
0
6

Year Published

2003
2003
2014
2014

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 6 publications
0
4
0
6
Order By: Relevance
“…3,24,25 Sulfide anion can act as a versatile intermediate through which sulfur with other species can be determined, since their high reactivity provides various means of detection. [27][28][29][30][31][32][33][34][35][36][37][38][39] In this sense, the coupling of flow injection analysis (FIA) with different detection strategies can be considered to be a good alternative for sulfide determination. Such a feature is assured to be due to outstanding advantages of the FIA system, such as simplicity, little sample manipulation, low reagents and sample consumption and, consequently, low-waste outcome.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations
“…3,24,25 Sulfide anion can act as a versatile intermediate through which sulfur with other species can be determined, since their high reactivity provides various means of detection. [27][28][29][30][31][32][33][34][35][36][37][38][39] In this sense, the coupling of flow injection analysis (FIA) with different detection strategies can be considered to be a good alternative for sulfide determination. Such a feature is assured to be due to outstanding advantages of the FIA system, such as simplicity, little sample manipulation, low reagents and sample consumption and, consequently, low-waste outcome.…”
Section: Introductionmentioning
confidence: 99%
“…Such a feature is assured to be due to outstanding advantages of the FIA system, such as simplicity, little sample manipulation, low reagents and sample consumption and, consequently, low-waste outcome. [31][32][33][34][35][36][37] The segmented flow analysis technique is considered to be a precursor of the different models of flow systems available today, based on sequential aspiration of the sample and air bubbles that make the flow dispersion better controlled. 37 Nowadays, there are several flow system configurations, such as: conventional flow-injection analysis with continuous flow and no air bubbles, proposed by Ruzicka; 38 a system with only one liquid segment trapped between two gas segments, which was named monosegmented; a system that employs several solenoid valves, named multicommutation; and a sequential analysis system.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…O resultado de tal ocorrência é o surgimento da dupla camada elétrica, DCE, região na qual há uma distribuição espacial não homogênea de carga [12,13] . Cabe observar que a análise por injeção em fluxo não abrange, por convenção [14] , a cromatografia nem a eletroforese capilar, apesar destas duas famílias de técnicas se basearem em fluxo de soluções.…”
Section: Introductionunclassified