2009
DOI: 10.1590/s0100-39842009000200005
|View full text |Cite
|
Sign up to set email alerts
|

Avaliação da dose no reto em pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do câncer do colo uterino

Abstract: OBJETIVO: O objetivo deste trabalho foi desenvolver um sistema dosimétrico termoluminescente capaz de avaliar as doses administradas ao reto de pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do câncer do colo uterino. MATERIAIS E MÉTODOS: O material termoluminescente utilizado para a avaliação da dose no reto foi o LiF:Mg,Ti,Na na forma de pó. O pó foi separado em pequenas porções de 34 mg, que foram acomodadas em um tubo capilar. Este tubo foi colocado em uma sonda retal, que era … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
2
0
4

Year Published

2010
2010
2019
2019

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 10 publications
0
2
0
4
Order By: Relevance
“…In the classical radiotherapy planning, the following parameters are utilized as limits for the anterior and posterior fields: the transition between the fourth and fifth lumbar vertebrae, the lower border of the obturator foramen or pubis, depending on the vaginal involvement, and laterally, at 1.5 cm from the small pelvis margin. For the lateral fields, the anterior border (AB) is the pubic symphysis, and the posterior border (PB) is the transition between the second and third sacral vertebrae (S2-S3) or including the whole vertebra S3 (4) . All the patients underwent pelvic MRI before initiating the treatment.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In the classical radiotherapy planning, the following parameters are utilized as limits for the anterior and posterior fields: the transition between the fourth and fifth lumbar vertebrae, the lower border of the obturator foramen or pubis, depending on the vaginal involvement, and laterally, at 1.5 cm from the small pelvis margin. For the lateral fields, the anterior border (AB) is the pubic symphysis, and the posterior border (PB) is the transition between the second and third sacral vertebrae (S2-S3) or including the whole vertebra S3 (4) . All the patients underwent pelvic MRI before initiating the treatment.…”
Section: Methodsmentioning
confidence: 99%
“…Teletherapy is a technique where the radiation source is distant from the target lesion, and is utilized in the treatment of the whole pelvis, including the lesion, uterus, vagina, parametrium and the regional lymphatic system. In brachytherapy, the radiation source is placed in direct contact with the target volume to be treated (3)(4)(5) .…”
Section: Introductionmentioning
confidence: 99%
“…Por meio de uma adaptação do método de Yamashita [5] 3 . Esse valor é obtido através de estequiometria.…”
Section: Metodologiaunclassified
“…Os detectores termoluminescentes são geralmente compostos de um único material e possuem tamanho pequeno, tornando a leitura do detector independente da distribuição angular da radiação. As maiores desvantagens dos dosímetros termoluminescentes são a demora na leitura do sinal e a perda do sinal após o processo de leitura [2,3].…”
Section: Introductionunclassified
“…Podem ocorrer sangramentos, ulceração ou estenose do reto, obstrução intestinal, hematúria entre outros. As complicações podem variar de leve a grave(OLIVEIRA, 2013;OLIVEIRA, et al, 2009). O tratamento do câncer do colo uterino depende de um estadiamento clínico o qual é apontado pela Federação Internacional de Ginecologia e Obstetríca (FIGO) onde é separado da seguinte maneira:Estágio I…”
unclassified