2013
DOI: 10.1590/s0034-72802013000600002
|View full text |Cite
|
Sign up to set email alerts
|

Best waveform score for diagnosing keratoconus

Abstract: Purpose: To test whether corneal hysteresis (CH) and corneal resistance factor (CRF) can discriminate between keratoconus and normal eyes and to evaluate whether the averages of two consecutive measurements perform differently from the one with the best waveform score (WS) for diagnosing keratoconus. Methods: ORA measurements for one eye per individual were selected randomly from 53 normal patients and from 27 patients with keratoconus. Two groups were considered the average (CH-Avg, CRF-Avg) and best waveform… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

2016
2016
2022
2022

Publication Types

Select...
5

Relationship

4
1

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 23 publications
0
2
0
1
Order By: Relevance
“…Ademais, também realizaram a análise das propriedades biomecânicas da córnea pelo método analisador de resposta ocular (ORA) 2 . Já Luz et al determinaram que as melhores medidas do escore da forma de onda (WS) foram superiores à média das medidas consecutivas da ORA para o diagnóstico de ceratocone 11 .…”
Section: Resultsunclassified
“…Ademais, também realizaram a análise das propriedades biomecânicas da córnea pelo método analisador de resposta ocular (ORA) 2 . Já Luz et al determinaram que as melhores medidas do escore da forma de onda (WS) foram superiores à média das medidas consecutivas da ORA para o diagnóstico de ceratocone 11 .…”
Section: Resultsunclassified
“…Hence, analyzing biomechanical properties of normal and subclinical KC eyes has gained special relevance. [25][26][27][28] Biomechanical characterization is still challenging because of several biasing factors, such as the intraocular pressure and corneal thickness. While other noncontact tonometer, the Reichert ORA (Buffalo, NY, USA) monitors corneal applanation response through the reflex of an infrared beam with diagnostic capability to detect ectasia, [29][30][31] ultra-high-speed Scheimpflug camera provides a dynamic visualization of the corneal deformation process with detailed information of the deformation response obtained during the NCT.…”
Section: Discussionmentioning
confidence: 99%
“…11 We used the examination with the best waveform score (ie, the best quality measurement) after four consecutive measurements. All ORA and Pentacam data were obtained by the same experienced operator (BV) in a consistent way during office hours.…”
Section: Methodsmentioning
confidence: 99%