2005
DOI: 10.1590/s0004-27492005000400017
|View full text |Cite
|
Sign up to set email alerts
|

Avaliação quantitativa das dimensões óculo-palpebrais em portadores de cavidade anoftálmica em uso de prótese ocular externa

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2007
2007
2016
2016

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 5 publications
0
3
0
Order By: Relevance
“…Today, worldwide, the number of patients who have been formally indicated for these types of surgeries continues to be high (1,2) . Besides the feeling of loss of the eyeball, the evisceration or enucleation predisposes the individual to esthetic defects such as enophthalmos, deepening of the eyelid superior sulcus, ptosis, incomplete transference of movement to the prosthesis, reduction of the lower fornix, and flaccidity of the lower eyelid (3) . In an attempt to reduce these disappointing results, biotechnology has provided the ophthalmology with a vast array of implants and prostheses, increasingly enhanced for functional plasticity, biocompatibility, and body integration (4,5) .…”
Section: Introductionmentioning
confidence: 99%
“…Today, worldwide, the number of patients who have been formally indicated for these types of surgeries continues to be high (1,2) . Besides the feeling of loss of the eyeball, the evisceration or enucleation predisposes the individual to esthetic defects such as enophthalmos, deepening of the eyelid superior sulcus, ptosis, incomplete transference of movement to the prosthesis, reduction of the lower fornix, and flaccidity of the lower eyelid (3) . In an attempt to reduce these disappointing results, biotechnology has provided the ophthalmology with a vast array of implants and prostheses, increasingly enhanced for functional plasticity, biocompatibility, and body integration (4,5) .…”
Section: Introductionmentioning
confidence: 99%
“…Qualitative and quantitative analysis were made using the Scion Image Program. The image processing allowed objective evaluations of the measures, contributing to the patient follow-up (27) . This was also observed in the measurements of this study, which were adequate, simple and reliable in enucleated patients.…”
Section: Discussionmentioning
confidence: 99%
“…While tracking objects, the eyes rotate only approximately 10º to 15º before head turn naturally occurs (27) . In this study, all results are higher than 15º and artificial eye motility at the central visual field can be considered acceptable for both orbital implants.…”
Section: Discussionmentioning
confidence: 99%