2004
DOI: 10.1590/s0004-27492004000600017
|View full text |Cite
|
Sign up to set email alerts
|

Lentes de contato esclerais: experiência inicial no Setor de Lentes de Contato da Universidade Federal de São Paulo/Escola Paulista de Medicina

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
0
0
1

Year Published

2008
2008
2023
2023

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 5 publications
0
0
0
1
Order By: Relevance
“…As regard to the therapeutic indications of scleral lens, the main conditions are scarring diseases of the cornea and conjunctiva (Stevens-Johnson syndrome, ocular cicatricial pemphigoid, cicatricial entropion, and post herpetic keratitis) and cases of severe dry eye (exposure keratopathy, congenital deficiency of the meibomian glands, superior limbic keratoconjunctivitis, and Sjögren syndrome) (8)(9)(10)(11)(12)(13)(14)(15)(16) . This kind of use is related to lacrimal retention between the cornea and lens and ocular protection in cases of exposure keratitis and eyelid or eyelash abnormalities.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…As regard to the therapeutic indications of scleral lens, the main conditions are scarring diseases of the cornea and conjunctiva (Stevens-Johnson syndrome, ocular cicatricial pemphigoid, cicatricial entropion, and post herpetic keratitis) and cases of severe dry eye (exposure keratopathy, congenital deficiency of the meibomian glands, superior limbic keratoconjunctivitis, and Sjögren syndrome) (8)(9)(10)(11)(12)(13)(14)(15)(16) . This kind of use is related to lacrimal retention between the cornea and lens and ocular protection in cases of exposure keratitis and eyelid or eyelash abnormalities.…”
Section: Discussionmentioning
confidence: 99%
“…• Lens insertion requires a relative motor skill, with adequate head position and precise hand movements to prevent leakage of the fluid chamber or air bubbles trapped under the lens. Hypoxia is a major concern mainly in some situations such as in post-keratoplasty fitting; may occur in some cases, mainly in lenses made of low-Dk materials, which are rare nowadays; and may be linked to excessive vaulting and/or high-thickness lenses (6)(7)(8)(9)(10)(11)(12)(13)(14) . Thus, scleral lenses are optical and therapeutic devices that may be an excellent option when soft or rigid gas-permeable (RGP) corneal lenses cannot be successfully fit.…”
Section: Clinical Experience With Adjustable Scleral Lensesmentioning
confidence: 99%
“…Alguns autores descrevem também o uso de LC esclerais, que teriam como indicações visuais em crianças as ectasias corneanas primárias como ceratocone, ceratoglobo e degeneração marginal pelúcida e ainda afacias, altas miopias e pós-operatórios de transplante de córnea. As indicações terapêuticas destas lentes seriam principalmente na síndrome de Stevens-Johnson, mas também no penfigóide ocular cicatricial, ceratopatia de exposição, ceratites pós-herpéticas, Sjögren, deficiência congê-nita das glândulas de Meibomius e a ceratoconjuntivite límbica superior (12) . Para uso contínuo como lente terapêutica em crianças têm-se preferido a lente de contato silicone-hidrogel que se mostra cada vez mais eficaz e segura nessa faixa etária (13) .…”
Section: Resumo Introduçãounclassified