2017
DOI: 10.1590/2446-4740.03217
|View full text |Cite
|
Sign up to set email alerts
|

Low cost system to measure active power in electrosurgical units

Abstract: Introduction: The real-time measurement of active power delivered to patients during the electrosurgical act is still an engineering challenge. Besides, there is no electrosurgical unit on the market capable of doing it according to the normative requirement. Methods: This work presents the design of an electronic structure capable to probe the electrosurgical equipment output electrical signals, using low-costs very common resistors, and High Frequency distortions compensation circuits, and process them to pr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0
1

Year Published

2020
2020
2022
2022

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 5 publications
(6 reference statements)
0
1
0
1
Order By: Relevance
“…Model sistem ESG untuk kontrol termal perangkat bedah elektro bipolar yang akurat memprediksi tingkat penyebaran termal khususnya elektroda dan jaringan [6]. Penggunaan tegangan frekuensi tinggi, lebih tinggi dari 200 Vpeak, dan kepadatan arus tinggi, menghasilkan bunga api, adalah prinsip sinyal bedah listrik [7]. Ada hubungan yang jelas antara pengaturan daya operasi elektro dan penyebaran superfisial kerusakan jaringan namun efek pengaturan daya dan jaringan dalam penetrasi tidak TEKNOKES, Vol.…”
Section: Pendahuluanunclassified
“…Model sistem ESG untuk kontrol termal perangkat bedah elektro bipolar yang akurat memprediksi tingkat penyebaran termal khususnya elektroda dan jaringan [6]. Penggunaan tegangan frekuensi tinggi, lebih tinggi dari 200 Vpeak, dan kepadatan arus tinggi, menghasilkan bunga api, adalah prinsip sinyal bedah listrik [7]. Ada hubungan yang jelas antara pengaturan daya operasi elektro dan penyebaran superfisial kerusakan jaringan namun efek pengaturan daya dan jaringan dalam penetrasi tidak TEKNOKES, Vol.…”
Section: Pendahuluanunclassified
“…In [ 16 ], the authors proposed an accelerometer and gyroscope based portable emissions measurement system technology to correct the output power of the ESU according to the speed of the active electrode. In [ 26 ], the authors suggested that the ESU can measure the active power in real-time that is delivered to the patient during surgery. The results indicated an error rate of less than 5%, and it succeeded to regulate the power of the ESU.…”
Section: Introductionmentioning
confidence: 99%