2021
DOI: 10.1590/2175-8239-jbn-2020-0234
|View full text |Cite
|
Sign up to set email alerts
|

Utilizing point-of-care ultrasound in the cardiorenal clinic to enhance patient care

Abstract: Utilizing point-of-care ultrasound in the cardiorenal clinic to enhance patient careA utilização de ultrassom point-of-care na clínica cardiorrenal para melhorar o atendimento ao paciente

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 5 publications
0
7
0
Order By: Relevance
“…Lung ultrasound was not suggestive of congestion and consisted of predominantly A‐line pattern. While one may argue these findings could be seen in chronic pulmonary hypertension, in our experience from the cardiorenal clinic at our institution, 7 portal vein tends to be less congested compared to hepatic and intrarenal veins even in patients with severe chronic pulmonary hypertension. This is likely because central venous pressure is not completely transmitted to portal vein through the hepatic sinusoidal system as opposed to hepatic vein, which is a direct tributary of the IVC 8 .…”
Section: Case Presentationmentioning
confidence: 63%
“…Lung ultrasound was not suggestive of congestion and consisted of predominantly A‐line pattern. While one may argue these findings could be seen in chronic pulmonary hypertension, in our experience from the cardiorenal clinic at our institution, 7 portal vein tends to be less congested compared to hepatic and intrarenal veins even in patients with severe chronic pulmonary hypertension. This is likely because central venous pressure is not completely transmitted to portal vein through the hepatic sinusoidal system as opposed to hepatic vein, which is a direct tributary of the IVC 8 .…”
Section: Case Presentationmentioning
confidence: 63%
“…Users with additional training in Doppler echocardiography assess additional parameters such as cardiac output and its response to fluid administration, LV filling pressures and right ventricular filling pressures at the bedside. 39 Venous Doppler:…”
Section: Right Atrial Pressurementioning
confidence: 99%
“…Therefore, IVC ultrasound should be interpreted in conjunction with other POCUS findings and the overall clinical picture. Users with further training in Doppler echocardiography assess additional parameters, such as cardiac output and its response to fluid administration, LV filling pressures, and right ventricular filling pressures at the bedside (39).…”
Section: Right Atrial Pressurementioning
confidence: 99%
“…In addition to quantification of congestion and prognostic significance, serial monitoring of these waveforms provides a real-time appraisal of the efficacy of decongestive therapy, as reported in multiple case studies. 39 , 40 , 41 , 42 , 43 , 44 , 45 Following are 2 case examples from our practice.…”
Section: Role In Patient Monitoringmentioning
confidence: 99%