2019
DOI: 10.1590/1679-78255510
|View full text |Cite
|
Sign up to set email alerts
|

Seismic Upgrading of Exterior Reinforced Concrete Frame with Small Column and Joint Area Using Externally Attached Steel Column

Abstract: This paper presents cyclic load test of five exterior reinforced concrete frames. All the specimens represent a substandard single-span, low-rise reinforced concrete frame building which behaves a weak column-strong beam mechanism under a strong seismic loading. The first three exterior frames M1, M2 and M3 were designed for the joint shear critical to investigate the effect of joint reinforcement. They are similar except the joint reinforcement detailing. The fourth specimen M4 was an exterior frame with a ve… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 14 publications
0
1
0
Order By: Relevance
“…As a result, columns must be designed with a significant safety margin, more than any other structural members, to avoid crushing of concrete and/or lateral buckling failure (Al-Rousan (2020), Al-Rousan and Issa (2018), Issa et al (2009), Al-Rousan and Barfed (2019), Abdalla et al (2019)). RC structures are sometimes subjected to deficiency due to one or more: physical and/or chemical changes, electrochemical effects, or fire attacks (Al-Rousan and AL-Tahat (2020), Thipprasert et al (2019), Bolukbas and Mete (2020), Yhya Laseima et al 2020, Beydokhti and Shariatmadar (2016). With the development of sophisticated quality control programs to measure quality and design features of structures, failure of concrete columns is diminishing significantly.…”
Section: Introductionmentioning
confidence: 99%
“…As a result, columns must be designed with a significant safety margin, more than any other structural members, to avoid crushing of concrete and/or lateral buckling failure (Al-Rousan (2020), Al-Rousan and Issa (2018), Issa et al (2009), Al-Rousan and Barfed (2019), Abdalla et al (2019)). RC structures are sometimes subjected to deficiency due to one or more: physical and/or chemical changes, electrochemical effects, or fire attacks (Al-Rousan and AL-Tahat (2020), Thipprasert et al (2019), Bolukbas and Mete (2020), Yhya Laseima et al 2020, Beydokhti and Shariatmadar (2016). With the development of sophisticated quality control programs to measure quality and design features of structures, failure of concrete columns is diminishing significantly.…”
Section: Introductionmentioning
confidence: 99%