2018
DOI: 10.1590/1679-78254845
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of a tuned liquid column damper in non-linear structures subjected to seismic excitations

Abstract: The behavior of the tuned liquid column damper (TLCD) is analyzed in the control of non-linear structures subjected to random seismic excitations. The structure is modeled as a system of one degree of freedom with incursion in the non-linear range. The Bouc-Wen hysteretic model is used to model the non-linear behavior of the structure. A stationary stochastic analysis is performed in the domain of the frequency. An equivalent statistical linearization was used for the analysis of the main system and the TLCD. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0
9

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 11 publications
(13 citation statements)
references
References 24 publications
0
4
0
9
Order By: Relevance
“…The results presented by Souza (2003) point out that the performance of the TLCD is comparable to the other types of liquid attenuators, but with the advantage of using a smaller amount of mass, with more stable behavior, shorter reaction time, and greater flexibility of sizing. Additionaly, Ghosh and Basu (2004); Chakraborty et al (2012) and Espinoza et al (2018) verify the efficiency of the TLCD in the control of seismic excitations. The tuned liquid column damper can also ensure operational safety and increase the fatigue life of the structures to which they are coupled as Shahrabi and Bargi (2019) demonstrate through an analytical and numerical study.…”
Section: Introductionmentioning
confidence: 84%
“…The results presented by Souza (2003) point out that the performance of the TLCD is comparable to the other types of liquid attenuators, but with the advantage of using a smaller amount of mass, with more stable behavior, shorter reaction time, and greater flexibility of sizing. Additionaly, Ghosh and Basu (2004); Chakraborty et al (2012) and Espinoza et al (2018) verify the efficiency of the TLCD in the control of seismic excitations. The tuned liquid column damper can also ensure operational safety and increase the fatigue life of the structures to which they are coupled as Shahrabi and Bargi (2019) demonstrate through an analytical and numerical study.…”
Section: Introductionmentioning
confidence: 84%
“…Donde PGA es el peak ground acceleration considerado, correspondiente a 0.3g para este estudio, de modo que el sistema se asume dentro del rango lineal. Para verificar este supuesto se debe plantear un modelo histerético donde sea posible evaluar si la rigidez se degrada o no (Espinoza et al, 2018a). Se presenta a continuación la ecuación de Lyapunov:…”
Section: Cálculo De Matriz De Covarianzaunclassified
“…Luego, Di Matteo et al (2017) concluyen que a pesar de que los ACLS producen un rendimiento menor, en comparación con los AMS, poseen facilidad de mantenimiento y son más baratos. Espinoza et al (2018b) investigan la eficiencia del ACLS en el control del desplazamiento de la estructura y el daño generado cuando la estructura posee comportamiento no lineal y está sometida a una excitación sísmica estocástica. Wang et al (2016) proponen un dispositivo que combina un AMS con un ACLS denominado Amortiguador Combinado Sintonizado (ACS).…”
Section: 58-67unclassified