Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization

Abstract: NiTi instruments have a high risk of separation due to torsional or flexural fatigue (cyclic fatigue). Chemomechanical preparation, cleaning procedures, chemical disinfection and sterilization cause the corrosion of endodontic instruments that may weaken the fracture resistance of the instruments. ObjectiveTo assess the effects of NaOCl immersion and autoclave sterilization on the cyclic fatigue resistance of ProFile, FlexMaster, Mtwo and TwistedFiles NiTi instruments (tip size 25, 0.06 taper, n=160).Material … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
40
5
3

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 37 publications
(50 citation statements)
references
References 31 publications
2
40
5
3
Order By: Relevance
“…In several studies, R-phase instruments revealed superior resistance to cyclic fatigue (Gambarini et al 2008a, Larsen et al 2009, Kim et al 2010, Pedull a et al 2011, Rodrigues et al 2011, Bhagabati et al 2012, Bouska et al 2012, P erez-Higueras et al 2013, Bulem et al 2013, Aminsobhani et al 2015) and superior flexibility compared with conventional NiTi without heat treatment (Gambarini et al 2008b,c, Hou et al 2011, Shen et al 2013c, Choi et al 2016. The load-deflection curve of TF instruments displays a narrower stress hysteresis including a lower plateau on loading than conventional NiTi (Hou et al 2011, Shen et al 2013c, implying that less stress is required to induce SIM formation whilst more austenite can be transformed to martensite (Liaw et al 2007).…”
Section: R-phasementioning
confidence: 99%
“…In several studies, R-phase instruments revealed superior resistance to cyclic fatigue (Gambarini et al 2008a, Larsen et al 2009, Kim et al 2010, Pedull a et al 2011, Rodrigues et al 2011, Bhagabati et al 2012, Bouska et al 2012, P erez-Higueras et al 2013, Bulem et al 2013, Aminsobhani et al 2015) and superior flexibility compared with conventional NiTi without heat treatment (Gambarini et al 2008b,c, Hou et al 2011, Shen et al 2013c, Choi et al 2016. The load-deflection curve of TF instruments displays a narrower stress hysteresis including a lower plateau on loading than conventional NiTi (Hou et al 2011, Shen et al 2013c, implying that less stress is required to induce SIM formation whilst more austenite can be transformed to martensite (Liaw et al 2007).…”
Section: R-phasementioning
confidence: 99%
“…As in the canal instrumentation, the working part of retreatment instruments contacts dynamically the NaOCl solution for a few minutes during the removal of root canal filling material. Several authors have studied the effect of NaOCl on cyclic fatigue resistance of NiTi instruments used for canal preparation [12][13][14]. However, there is no study evaluating the fatigue behavior of retreatment instruments after immersion in NaOCl solution.…”
Section: Introductionmentioning
confidence: 99%
“…Os instrumentos selecionados para essa análise foram colocados em pequenos recipientes de vidro, separados com a quantidade de solução de NaOCl a 37°C, necessária para contatar 16mm do comprimento do instrumento. A imersão foi realizada de forma dinâmica por 3 mim (Bulem et al, 2013;Pedullá et al, 2018) Para a avaliação em EDX, selecionamos aleatoriamente três instrumentos dos grupos (2, 3, 6 e 7). Antes das análises, os instrumentos foram identificados através de um número registrado no cabo.…”
Section: A Imersão Em Hipoclorito De Sódiounclassified
“…O trabalho mostrou que repetidos ciclos de esterilziação diminuiu à resistência flexural dos instrumentos Twisted File, mas não afetou o comportamento dos instrumentos HyFlex CM. A imersão em hipoclorito de sódio não influenciou na resistência à fadiga cíclica de todos os instrumentos testados nesse trabalho Bulem et al (2013). estudaram sobre a resistência à fadiga cíclica de diferentes instrumentos de NiTi após imersão em hipoclorito de sódio e ou ciclos de esterilização.…”
unclassified