2018
DOI: 10.1590/1678-7757-2016-0590
|View full text |Cite
|
Sign up to set email alerts
|

Reliability of light microscopy and a computer-assisted replica measurement technique for evaluating the fit of dental copings

Abstract: The aim of this in vitro study was to assess the reliability of two measurement systems for evaluating the marginal and internal fit of dental copings.Material and MethodsSixteen CAD/CAM titanium copings were produced for a prepared maxillary canine. To modify the CAD surface model using different parameters (data density; enlargement in different directions), varying fit was created. Five light-body silicone replicas representing the gap between the canine and the coping were made for each coping and for each… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
1
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 28 publications
1
1
0
Order By: Relevance
“…The results of this clinical study did not show a significant difference between the three evaluation methods (D-IOS, D-GOM, and CV-SR) regarding the internal fit. Rudolph et al investigated a digital replica method with laboratory software, which is comparable to D-GOM in this study [48]. They did not find a significant difference between the conventional silicone replica technique and their digital replica method, which is in good accordance with our results.…”
Section: Discussionsupporting
confidence: 91%
“…The results of this clinical study did not show a significant difference between the three evaluation methods (D-IOS, D-GOM, and CV-SR) regarding the internal fit. Rudolph et al investigated a digital replica method with laboratory software, which is comparable to D-GOM in this study [48]. They did not find a significant difference between the conventional silicone replica technique and their digital replica method, which is in good accordance with our results.…”
Section: Discussionsupporting
confidence: 91%
“…After setting, the silicone replica can be sectioned and measured [ 33 ]. This straightforward and inexpensive method has been proven a reliable and accurate alternative to the destructive cross-sectional method [ 35 , 36 ]. RT has also been modified by making an external impression of the fixed crown on the corresponding abutment and pouring epoxy resin material after setting of the silicone.…”
Section: Introductionmentioning