2016
DOI: 10.1590/1678-4162-8096
|View full text |Cite
|
Sign up to set email alerts
|

Change in physical and chemical characteristics related to the binomial time-temperature used in sous pasteurization see Tambaqui (Colossoma macropomum)

Abstract: The goal of this study was to evaluate sous vide fish and assess the influence of time and temperature on the pasteurization process through quality parameters. The raw material (tambaqui fillets) and the sous vide underwent physical, physicochemical, and microbiological analyses. A sauce was prepared containing soy sauce, water, horseradish and garlic flakes. The product's pasteurization parameters of time and temperature were defined according to a 2 2 central composite rotatable design (CCRD), and the depen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
9
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(12 citation statements)
references
References 19 publications
3
9
0
Order By: Relevance
“…Based on the response surface graphs and the desirability function (Figure 3), the optimized operating conditions can be set for the development of pirarucu fillet sous vide in the evaluated experimental area, and the optimum time–temperature conditions used at the laboratory scale are 60 ℃ and 568.8 s, with a desirability value of 0.80. This temperature is similar to that reported by Kato et al. (2016) and Cosansu et al.…”
Section: Resultssupporting
confidence: 91%
See 4 more Smart Citations
“…Based on the response surface graphs and the desirability function (Figure 3), the optimized operating conditions can be set for the development of pirarucu fillet sous vide in the evaluated experimental area, and the optimum time–temperature conditions used at the laboratory scale are 60 ℃ and 568.8 s, with a desirability value of 0.80. This temperature is similar to that reported by Kato et al. (2016) and Cosansu et al.…”
Section: Resultssupporting
confidence: 91%
“…The parameters of time–temperature of the sous vide process were defined according to a 2 2 full factorial design in a rotational central composite design (CCD), consisting of four linear trials at two levels (+1 and −1), with axial points −α and +α (−1.41 and +1.41, respectively), and three trials at the centre point as recommended by Kato et al. (2016).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations