Preliminary Mechanical Test of Proximal Femur Reinforcement With Cemented X-Shaped Pmma

Abstract: Objective:To evaluate the mechanical behavior of the proximal end of the femur submitted to the X-shaped polymethylmethacrylate (PMMA) reinforcement technique.Methods:Fifteen synthetic femurs, with a Nacional® density of 10 PCF, were divided into two groups: the DX group, with 5 units that were submitted to PMMA reinforcement, and the DP group, with 10 units, which were evaluated intact. The volume of PMMA required, the maximum load, and the absorbed energy to fracture were analyzed by means of a static mechan… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 19 publications
(21 reference statements)
0
2
0
Order By: Relevance
“…A total of 60% of studies embedded their specimen in the popular Hayes‐fall (or Courtney‐fall) configuration, with the femoral neck at 15° anteversion and the shaft at 10° to the horizontal 27 . We found little agreement in how studies represented soft tissue over the greater trochanter; authors used approaches like custom‐shaped bone cement, 26,28 a rubber mat, 16 or silicone 15,29,30 …”
Section: Resultsmentioning
confidence: 96%
See 1 more Smart Citation
“…A total of 60% of studies embedded their specimen in the popular Hayes‐fall (or Courtney‐fall) configuration, with the femoral neck at 15° anteversion and the shaft at 10° to the horizontal 27 . We found little agreement in how studies represented soft tissue over the greater trochanter; authors used approaches like custom‐shaped bone cement, 26,28 a rubber mat, 16 or silicone 15,29,30 …”
Section: Resultsmentioning
confidence: 96%
“…27 We found little agreement in how studies represented soft tissue over the greater trochanter; authors used approaches like custom-shaped bone cement, 26,28 a rubber mat, 16 or silicone. 15,29,30 Measured outcomes varied across studies but tended to use comparative measures like change in fracture load and energy as primary end points (Table S1). When compared to maximum failure loads in the control group, augmentations resulted in femurs ranging from 58% weaker (IM nailing 20 ) or 82% stronger (PMMA injections 31 ).…”
Section: Resultsmentioning
confidence: 99%