Method to Determine the Root Canal Anatomic Dimension by using a New Cone-Beam Computed Tomography Software

Abstract: This study discusses a method to determine the root canal anatomic dimension by using e-Vol DX software. The methodology consists in initially establishes the correct positions which will be measured, define the point on the edge of the anatomical structure, and next adjust the intermediate position in the grayscale of CBCT image. Afterward, thin sections (0.10 mm) are obtained from 3D reconstructed slices in the filter for the measurements, in order to determine the edge of the anatomical surface in the axial… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
14
0
4

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 19 publications
(23 citation statements)
references
References 24 publications
(38 reference statements)
0
14
0
4
Order By: Relevance
“…Adjustments were made for parallax correction when necessary. A specific tool, used as a positioning guide and for the definition of edges and limits for measurements, was developed for micrometric measurements and applied using the e-Vol DX software, together with synchronization for color map analysis (17).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Adjustments were made for parallax correction when necessary. A specific tool, used as a positioning guide and for the definition of edges and limits for measurements, was developed for micrometric measurements and applied using the e-Vol DX software, together with synchronization for color map analysis (17).…”
Section: Discussionmentioning
confidence: 99%
“…For measurements, post diameters on the CBCT scans, the markings were synchronized on the samples according to X-, Y-and Z-axes and, when necessary, CBCT scans were repositioned to correct parallax errors. The e-Vol DX software was used to measure the diameter of the posts on the CBCT scans included in this study (13,17). The exact points to be measured, such as the marking on the edge of the anatomic structures, were defined, and the intermediate grade of the grayscale was adjusted on the CBCT scan.…”
Section: Measurement Of Specimens Using the E-vol DX Softwarementioning
confidence: 99%
See 1 more Smart Citation
“…As avaliações do volume das câmaras pulpares, no presente estudo, foram realizadas apenas por um avaliador, pois trata-se de imagens com dimensões muito pequenas, o que dificulta a Pesquisa VOLUME DA CÂMARA PULPAR DE MOLARES SUPERIORES E INCISIVOS INFERIORES repetição das medições, além de estabelecer variáveis de confusão (vieses) para delimitar corretamente o ponto de referência. Uma vez que a medição é repetida, dificilmente as referências serão delimitadas na posição correta 18 .…”
Section: Discussionunclassified
“…Currently the new high resolution CBCT scanners and specific softwares have im-proved the quality of tridimensional images (Bueno et al, 2018;Bueno et al, 2019;Estrela et al, 2018). Thus it has allowed a more precise analysis of the root canal anatomy and surround-ing tissues, which can be decisive to the dentist negotiated better the complex cases in endodontics (Bueno et al, 2018;Estrela et al, 2018).…”
Section: Authors (2021)mentioning
confidence: 99%