2005
DOI: 10.1107/s0021889805015918
|View full text |Cite
|
Sign up to set email alerts
|

Single-crystal neutron diffuse scattering and Monte Carlo study of the relaxor ferroelectric PbZn1/3Nb2/3O3(PZN)

Abstract: Full three‐dimensional diffuse neutron scattering data have been recorded from a single crystal of Pb(Zn1/3Nb2/3)O3 (PZN) at 300 K using the time‐of‐flight Laue technique on the SXD single‐crystal instrument at ISIS. The data show a series of diffuse rods of scattering oriented parallel to each of the six 〈1 1 0〉 crystal directions. Monte Carlo simulation has been used to demonstrate that the diffuse rods are caused by planar nanodomains oriented normal to the 〈1 1 0〉 directions. Within these domains, there ar… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
60
1

Year Published

2007
2007
2022
2022

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 56 publications
(66 citation statements)
references
References 15 publications
(12 reference statements)
5
60
1
Order By: Relevance
“…For each run 600 exposures of 60 s were recorded at 0.2 • intervals, making a total collection time of 10 h. The sample was contained in a cryofurnace but a collimator was used to eliminate scattering from this and only allow neutrons emitted radially from the sample at the centre of the furnace to reach the detector. The data shown in Figure 5c compare well with data shown in Figure 5a that were recorded earlier on SXD (see reference [16]). These SXD data were recorded in ∼ 20 h. The sample sizes in the two different experiments were comparable (175 mm 3 versus 192 mm 3 ).…”
Section: Measurement Of Diffuse Scattering On a Reactor Sourcesupporting
confidence: 78%
“…For each run 600 exposures of 60 s were recorded at 0.2 • intervals, making a total collection time of 10 h. The sample was contained in a cryofurnace but a collimator was used to eliminate scattering from this and only allow neutrons emitted radially from the sample at the centre of the furnace to reach the detector. The data shown in Figure 5c compare well with data shown in Figure 5a that were recorded earlier on SXD (see reference [16]). These SXD data were recorded in ∼ 20 h. The sample sizes in the two different experiments were comparable (175 mm 3 versus 192 mm 3 ).…”
Section: Measurement Of Diffuse Scattering On a Reactor Sourcesupporting
confidence: 78%
“…The fact that the diffuse scattering is only diminished below T c and, in particular, very anisotropic ͑being elongated strongly along one direction͒ and exhibits no memory is suggestive that the diffuse scattering is directly related to the polar structure in the relaxor ferroelectrics as described in several models. 19,41 An important result is that our measurements show a clear structural signature of two distinct temperature scales. At a high temperature, the diffuse scattering is onset and is insensitive to the application of an electric field.…”
Section: B Diffuse Scattering Near Q ᠬ = "003…mentioning
confidence: 79%
“…15,16 Several models describing the diffuse scattering in terms of phase-shifted polar nanoregions and static strain fields have been proposed. [17][18][19][20] We emphasize that all of these models relate the diffuse scattering to the presence of polar correlations in the material. Therefore investigating the effects of an external electric field on the diffuse scattering, direct information of the local polar correlations can be obtained.…”
Section: Introductionmentioning
confidence: 99%
“…2͑a͒. [16][17][18][19][20] Despite uncertainties in the origin of the diffuse-scattering cross section, the polar nature of the diffuse scattering in the lead-based relaxors has been established through three different means. First, the onset of the diffuse scattering in PMN was shown to coincide with the temperature at which a ferroelectric-active, soft, transverse-optic mode reaches a minimum frequency ͓see Fig.…”
Section: Introductionmentioning
confidence: 99%