1991
DOI: 10.1016/s0005-2728(09)91004-0
|View full text |Cite
|
Sign up to set email alerts
|

Mitochondrial bioenergetics as affected by DDT

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
60
0

Year Published

1994
1994
2018
2018

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 76 publications
(63 citation statements)
references
References 31 publications
3
60
0
Order By: Relevance
“…Mitochondrial membrane potential (⌬⌿) was estimated with an ion-selective electrode of TPP ϩ prepared according to Kamo et al (1979) to measure the transmembrane distribution of TPP ϩ as previously established (Kamo et al, 1979;Moreno and Madeira, 1991), using an Ag/AgCl-saturated electrode as reference (Model MI 402; Microelectrodes, Inc., Bedford, NH). The reactions were carried out in an open vessel with magnetic stirring at 25°C and performed with 1 mg mitochondrial protein in 2 ml of the standard respiratory medium supplemented with 2 M rotenone and 4 M TPP ϩ .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Mitochondrial membrane potential (⌬⌿) was estimated with an ion-selective electrode of TPP ϩ prepared according to Kamo et al (1979) to measure the transmembrane distribution of TPP ϩ as previously established (Kamo et al, 1979;Moreno and Madeira, 1991), using an Ag/AgCl-saturated electrode as reference (Model MI 402; Microelectrodes, Inc., Bedford, NH). The reactions were carried out in an open vessel with magnetic stirring at 25°C and performed with 1 mg mitochondrial protein in 2 ml of the standard respiratory medium supplemented with 2 M rotenone and 4 M TPP ϩ .…”
Section: Methodsmentioning
confidence: 99%
“…Control assays were conducted in the presence of an identical volume of ethanol to that used in the experiments with TAM. ⌬⌿ is expressed in mV and was estimated from the decrease of TPP ϩ concentration in the reaction medium, as described elsewhere (Moreno and Madeira, 1991). Preliminary calibrations in the presence of TAM revealed no direct interference with the electrode signal.…”
Section: Methodsmentioning
confidence: 99%
“…Mitochondrial Ca 2+ fluxes were measured by monitoring the changes in Ca 2+ concentration in the reaction medium using a Ca 2+ -selective electrode [25]. The reactions were conducted in an open vessel with magnetic stirring in 1 ml of the standard reaction medium supplemented with 5 mM glutamate/2.5 mM malate and 90 nmol/mg protein of CaCl 2 .…”
Section: Measurements Of Ca 2+ Fluxesmentioning
confidence: 99%
“…2 min of recording), Ca 2 + (200 nmol/mg protein) was added and Dc recorded for 12 additional minutes. Mitochondrial Dc was evaluated by the transmembrane distribution of TPP + as previously described [23,25].…”
Section: Measurement Of Mitochondrial Membrane Potentialmentioning
confidence: 99%