Ratiometric fluorescence method for malachite green detection based on dual-emission BSA-protected gold nanoclusters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
13
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 61 publications
(13 citation statements)
references
References 41 publications
0
13
0
Order By: Relevance
“…In view of this, it is necessary to exploit a rapid and practical method in testing MG. Many methods were used in MG measurement, such as surface-enhanced Raman spectroscopy (SERS), chromatography, spectrophotometry, etc. Most methods of detecting MG are based on spectrophotometry, such as UV–vis spectrophotometry, but the MG adsorption process by adsorbent usually takes a long time.…”
Section: Introductionmentioning
confidence: 99%
“…In view of this, it is necessary to exploit a rapid and practical method in testing MG. Many methods were used in MG measurement, such as surface-enhanced Raman spectroscopy (SERS), chromatography, spectrophotometry, etc. Most methods of detecting MG are based on spectrophotometry, such as UV–vis spectrophotometry, but the MG adsorption process by adsorbent usually takes a long time.…”
Section: Introductionmentioning
confidence: 99%
“…The two characteristic peaks at 84.1 and 87.6 eV were ascribed to Au 4f 7/2 and Au 4f 5/2 , suggesting the coexistence of Au(0) and Au(I) in the AuNCs of AMIT NPs. 43 The peaks at 642.1 and 653.5 eV were attributed to Mn 2p3/2 and Mn 2p1/2, suggesting that KMnO 4 was successfully reduced to MnO 2 during the preparation of AMIT NPs. 44 Furthermore, the coexistence of Au, Mn, O, and S in the elemental mapping images (Figure 1D) and representative peaks of each element in the EDS spectrum (Figure 1E) further proved the successful assembly of each component.…”
Section: ■ Results and Discussionmentioning
confidence: 96%
“…Fluorescence detection mostly adopts single-emission peak probe, which is affected by environmental variation, probe concentration change, and instrumental fluctuation [21] , [22] . Compared with single-emission fluorescence analysis, ratiometric fluorescence method adds internal standard calibration in the detection system, which has the advantages of high stability and low detection background [21] , [23] , [24] .…”
Section: Introductionmentioning
confidence: 99%