2009
DOI: 10.1002/bmc.1329
|View full text |Cite
|
Sign up to set email alerts
|

Liquid chromatography tandem mass spectrometry method for determination of bisoprolol in human plasma using d5‐bisoprolol as the internal standard

Abstract: A simple, reliable and sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) protocol was developed and validated for quantification of bisoprolol in human plasma. The sample was pretreated with a simple procedure of protein precipitation and an isotope-labeled d5-bisoprolol was used as internal standard. The chromatographic separation was performed on a Capcell Pak C(18) MG III column (100 mm x 2.0 mm, 5 microm). The protonated ion of the analyte was detected in positive ionization by multiple r… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 15 publications
0
4
0
Order By: Relevance
“…Protein precipitation technique was applied for the separation of bisoprolol in human plasma, with a recovery rate of about 94.03, 100.3 and 96.29% for 1.5, 40 and 80 ng/mL of bisoprolol, respectively. After analyzing the samples no interference normally present in plasma was detected [13].…”
Section: Protein Precipitation Techniquementioning
confidence: 99%
See 1 more Smart Citation
“…Protein precipitation technique was applied for the separation of bisoprolol in human plasma, with a recovery rate of about 94.03, 100.3 and 96.29% for 1.5, 40 and 80 ng/mL of bisoprolol, respectively. After analyzing the samples no interference normally present in plasma was detected [13].…”
Section: Protein Precipitation Techniquementioning
confidence: 99%
“…These methods include liquid chromatography coupled with mass spectrometry (LC-MS/MS) [7][8][9][10][11][12][13][14][15][16][17], liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS/MS) [18,19], gas chromatography coupled with mass spectrometry (GC-MS) [3,[20][21][22], high performance liquid chromatography (HPLC) [23,24], high performance liquid chromatography coupled with mass spectrometry (HPLC-MS) [25,26], high performance liquid chromatography with fluorescence detection (HPLC-FLD) [2,27,28], high performance liquid chromatography coupled with ultraviolet detection (HPLC-UV) [29], reversed-phase ultra-high-performance liquid chromatography coupled with mass spectrometry (UHPLC-MS) [30].…”
Section: Introductionmentioning
confidence: 99%
“…Recently, Liu et al reported a liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for the quantitation of bisoprolol in human plasma with a linearity range of 0.5-100 ng/ml. Plasma aliquots spiked with bisoprolol were processed using simple protein precipitation extraction method [5] followed by chromatographic separation of bisoprolol achieved on Capcell Pak C18 MG III column (100 mm × 2.0 mm, 5 μ), using gradient elution. Similarly, Hemavanthi G. et al reported an LC-electrospray ionization (ESI)-MS for determination of bisoprolol and triamterene in human plasma.…”
Section: Introductionmentioning
confidence: 99%
“…Recently, Liu et al reported a liquid chromatographytandem mass spectrometric (LC-MS/MS) method for the quantitation of bisoprolol in human plasma with a linearity range of 0.5-100 ng/ml. Plasma aliquots spiked with bisoprolol were processed using simple protein precipitation extraction method [3] followed by chromatographic separation of bisoprolol achieved on Capcell Pak C 18 MG III column (100 mm × 2.0 mm, 5 µ), using gradient elution.…”
Section: Introductionmentioning
confidence: 99%