2006
DOI: 10.1051/jp4:2006133016
|View full text |Cite
|
Sign up to set email alerts
|

10-kJ PW laser for the FIREX-I program

Abstract: A lO-kJ PW laser (LFEX) is under construction for the FlREX-I program. This paper reports a desigri overview of LFEX, the technological development of a large-aperture arrayed amplifier with modified four-pass architecture, wavefront correction, a large-aperture Faraday rotator with a superconducting magnet, a new pulse compressor arrangement,. and focus control.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
56
0
1

Year Published

2008
2008
2024
2024

Publication Types

Select...
10

Relationship

2
8

Authors

Journals

citations
Cited by 83 publications
(57 citation statements)
references
References 2 publications
0
56
0
1
Order By: Relevance
“…High-intensity petawatt laser facilities that deliver multipicosecond (ps) kilojoule (kJ) laser pulses have become available, such as OMEGA-EP [20], LFEX [21], PHELIX [22], PETAL [23], and NIF-ARC will become available soon [24]. In this new multi-ps kJ regime, the nature of preplasma heavily evolves with time, instabilities and self-generated electromagnetic fields grow significantly, thus the dynamics of LPI and the characteristics of fast electron generation are inherently different from those in the sub-ps regime.…”
mentioning
confidence: 99%
“…High-intensity petawatt laser facilities that deliver multipicosecond (ps) kilojoule (kJ) laser pulses have become available, such as OMEGA-EP [20], LFEX [21], PHELIX [22], PETAL [23], and NIF-ARC will become available soon [24]. In this new multi-ps kJ regime, the nature of preplasma heavily evolves with time, instabilities and self-generated electromagnetic fields grow significantly, thus the dynamics of LPI and the characteristics of fast electron generation are inherently different from those in the sub-ps regime.…”
mentioning
confidence: 99%
“…The experiments were performed using the Gekko XII and the LFEX laser system [6] at the Institute of Laser Engineering, Osaka University. The wavelength of the GXII laser was 0.53 micron and the pulse duration was 1.5 ns.…”
Section: Methodsmentioning
confidence: 99%
“…Nevertheless, due to poor relative stability and low thermal conductivity, Tb-doped glasses could not be employed in high-power lasers [16]. For another, TGG crystal, as a crystalline MO material, is a congruently melting material and therefore can be synthesized by the Czochralski (Cz) method.…”
Section: Introductionmentioning
confidence: 99%