2017 IEEE International Solid-State Circuits Conference (ISSCC) 2017
DOI: 10.1109/isscc.2017.7870325
|View full text |Cite
|
Sign up to set email alerts
|

10.7 A 25MHz 4-phase SAW hysteretic DC-DC converter with 1-cycle APC achieving 190ns t<inf>settle</inf> to 4A load transient and above 80% efficiency in 96.7% of the power range

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(3 citation statements)
references
References 4 publications
0
3
0
Order By: Relevance
“…6 (c)). An adaptive phase control is mostly used together with a multiple phase control [2], [7], [9], [11], [12], [15], [18]- [21], [23], [25]- [27], [29], [30], [32], [33], [43]- [45], [49]- [51], [55], [60], where each phase is shifted by 360/N degree (N is the total number of phases). This scheme can basically reduce the ripple current by the factor of N, or it can even perfectly cancel out the ripple current at certain duty.…”
Section: Design Strategy and Basic Circuit Techniquesmentioning
confidence: 99%
“…6 (c)). An adaptive phase control is mostly used together with a multiple phase control [2], [7], [9], [11], [12], [15], [18]- [21], [23], [25]- [27], [29], [30], [32], [33], [43]- [45], [49]- [51], [55], [60], where each phase is shifted by 360/N degree (N is the total number of phases). This scheme can basically reduce the ripple current by the factor of N, or it can even perfectly cancel out the ripple current at certain duty.…”
Section: Design Strategy and Basic Circuit Techniquesmentioning
confidence: 99%
“…The main difference between switching regulators and linear ones, is that switching regulators store power in one phase, and discharge it in a second phase, so the current is 90 o out of phase with the voltage, while linear regulators uses voltage drop to regulate the voltage. So, energy within switching regulators can be stored and recovered during the discharge phase of the switching cycle, which make them higher in efficiency and more attractive for EHS for IoT smart nodes [73][74][75][76][77][78][79][80][81][82][83][84]. Thus, for maximum charge transfer efficiency, the clock duty cycle tends to be 50% with a small non-overlap period to avoid shoot-through current.…”
Section: Switching Regulatorsmentioning
confidence: 99%
“…The maximum load current is defined by the class AB output swing. For a maximum differential output swing of 2.6V, the peak load current demanded by the amplifier is 2.6 V/16 Ω=162.5 mA.For the selection of the control schemes, hysteretic control has becoming very popular in recent years for its inherent fast loop response[47][48][49][50][51][52]. However, the switching frequency of the hysteretic converter is dependent on several design parameters such as the input and output voltages, load current, hysteresis window and so forth.…”
mentioning
confidence: 99%