2018
DOI: 10.3233/jnr-180056
|View full text |Cite
|
Sign up to set email alerts
|

1.5 GPa compact double-wall clamp cell for SANS and NSE studies at low temperatures and high magnetic fields

Abstract: Abstract.We have developed and realised a compact high-pressure clamp cell of the piston-cylinder type for Small Angle Neutron Scattering (SANS) and Neutron Spin Echo (NSE) spectroscopy measurements. The cell can pressurise 5 mm samples up to 1.5 GPa. It is non-magnetic, produces a sufficiently low and flat SANS background with a relatively good neutron transmission and can be used in combination with polarised neutrons. The cell accommodates samples of up to 55 mm 3 in volume and adopts a two-layer geometry: … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
10
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(11 citation statements)
references
References 21 publications
(24 reference statements)
0
10
0
Order By: Relevance
“…The diameter of NCA3 is Ø12.3 mm. The material of samples NCA1 and NCA3 has been used for producing the cell described in [18].…”
Section: Mg Kibble Et Al / Low-background Materials For High Pressmentioning
confidence: 99%
See 1 more Smart Citation
“…The diameter of NCA3 is Ø12.3 mm. The material of samples NCA1 and NCA3 has been used for producing the cell described in [18].…”
Section: Mg Kibble Et Al / Low-background Materials For High Pressmentioning
confidence: 99%
“…As a result, the main difficulty encountered in inelastic neutron scattering experiments is the issue of the neutron beam having to travel through rather thick sections of the pressure vessels which contain the sample under investigation [5,7]. This gives rise to unwanted absorption and coherent or incoherent background scattering which can be mitigated by the right choice of vessel material and the optimisation of a high-pressure vessel geometry design [8,18].…”
Section: Introductionmentioning
confidence: 99%
“…The pressure cell should also be non-magnetic down to very low temperatures to be used for polarized neutron scattering to reveal weak magnetism. Only a few high-strength materials satisfy these criteria [2][3][4].…”
Section: Introductionmentioning
confidence: 99%
“…The most common device for the high pressure neutron experiments is the clamp cell, also commonly used for magnetic measurements [2,[4][5][6][7]. Its characteristic feature is the application and fixation of the pressure ex situ, before the cell is transferred into the experimental setup.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation