Small single-institutional studies performed prior to the introduction of organ allocation using the Model for End-Stage Liver Disease (MELD) suggest that early airway extubation of liver transplant recipients is a safe practice. We designed a multicenter study to examine adverse events associated with early extubation in patients selected for liver transplantation using MELD score. A total of 7 institutions extubated all patients meeting study criteria and reported adverse events that occurred within 72 hours following surgery. Adverse events were uncommon: occurring in only 7.7% of 391 patients studied. Most adverse events were pulmonary or surgically related. Pulmonary complications were usually minor, requiring only an increase in ambient oxygen concentration. The majority of surgical adverse events required additional surgery. Analysis of a limited set of perioperative variables suggest that blood transfusions and technical factors were associated with an increased risk of adverse events. In conclusion, while early extubation appears to be safe under specified circumstances, there are performance differences between institutions that remain to be explained. Liver Transpl 13:1557Transpl 13: -1563Transpl 13: , 2007
Decreases in endothelial nitric oxide synthase derived nitric oxide (NO) production during liver transplantation promotes injury. We hypothesized that preemptive inhaled NO (iNO) would improve allograft function (primary) and reduce complications post-transplantation (secondary). Patients at two university centers (Center A and B) were randomized to receive placebo (n = 20/center) or iNO (80 ppm, n = 20/center) during the operative phase of liver transplantation. Data were analyzed at set intervals for up to 9-months post-transplantation and compared between groups. Patient characteristics and outcomes were examined with the Mann-Whitney U test, Student t-test, logistic regression, repeated measures ANOVA, and Cox proportional hazards models. Combined and site stratified analyses were performed. MELD scores were significantly higher at Center B (22.5 vs. 19.5, p<0.0001), surgical times were greater at Center B (7.7 vs. 4.5 hrs, p<0.001) and warm ischemia times were greater at Center B (95.4 vs. 69.7 min, p<0.0001). No adverse metabolic or hematologic effects from iNO occurred. iNO enhanced allograft function indexed by liver function tests (Center B, p<0.05; and p<0.03 for ALT with center data combined) and reduced complications at 9-months (Center A and B, p = 0.0062, OR = 0.15, 95% CI (0.04, 0.59)). ICU (p = 0.47) and hospital length of stay (p = 0.49) were not decreased. iNO increased concentrations of nitrate (p<0.001), nitrite (p<0.001) and nitrosylhemoglobin (p<0.001), with nitrite being postulated as a protective mechanism. Mean costs of iNO were $1,020 per transplant. iNO was safe and improved allograft function at one center and trended toward improving allograft function at the other. ClinicalTrials.gov with registry number 00582010 and the following URL:http://clinicaltrials.gov/show/NCT00582010.
P Pu ur rp po os se e: : Chondroblastic osteosarcoma requiring surgical intervention is associated with a high risk of pulmonary tumour embolism. Rapid intraoperative diagnosis with transesophageal echocardiography (TEE) allowed changing the management plan and treatment of a life-threatening pathology.
P Pu ur rp po os se e: : To report the case of a laparoscopic donor nephrectomy in which the preoperative evaluation of the patient gave no indication of the surgical difficulties that were encountered intraoperatively, resulting in substantial bleeding, a suspected gas embolism, and emergency conversion of the procedure from laparoscopic to open donor nephrectomy.C Cl li in ni ic ca al l f fe ea at tu ur re es s: : A 59-yr-old man -height: 175 cm, weight: 85.5 kg, American Society of Anesthesiologists physical status I -presented as kidney donor for laparoscopic donor nephrectomy. He was healthy, on no medication, and had no previous abdominal surgery or diseases of the urinary tract. The preoperative computed tomography (CT) scan evaluation of his kidneys confirmed this by reporting a normal bilateral renal and renal vascular anatomy. In contradiction to the preoperative CT scan findings, the surgeon discovered abnormalities in the operative field. This included extensive scarring surrounding the left kidney, adenopathy near the right hilum, and a large branch lumbar vein entering the renal vein. The large branch lumbar vein was clipped but the clips dislodged, causing significant blood loss, and a suspected gas embolus. The procedure was converted to an emergency open donor nephrectomy. Postoperatively the patient made a full recovery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.