Purpose: Retrospective, surrogate marker-based studies have found inconsistent associations between systemic iron overload (SIO) and adverse outcome in patients undergoing allogeneic stem cell transplantation (allo-SCT). As a consequence, the impact of SIO in this context remains under debate. The aim of this study was to test whether the objective pretransplant quantification of liver-iron content (LIC) by magnetic resonance imaging (MRI) could circumvent these limitations and conclusively define the prognostic relevance of SIO.Experimental Design: The correlation between pretransplant LIC and surrogate parameters as well as the impact of SIO on posttransplant outcome was assessed within an observational study of patients (n ¼ 88) with either myelodysplastic syndrome (MDS) or acute myeloid leukemia (AML) undergoing allo-SCT.Results: Ferritin levels of 1,000 ng/mL or more provided only poor specificity (31.8%) for predicting elevated LIC (!125 mmol/g) and even higher thresholds (!2,500 ng/mL) lacked an association with nonrelapse mortality (NRM). In contrast, LIC 125 mmol/g or more was a significant risk factor for NRM in uni-and multivariate analysis (HR ¼ 2.98; P ¼ 0.016). Multivariate Cox-regression further showed that LIC 125 mmol/g or more was associated with a decreased overall survival (HR ¼ 2.24, P ¼ 0.038), whereas ferritin or transfusion burden were not.Conclusions: SIO reflected by LIC is an independent negative prognostic factor for posttransplant outcome in patients with AML and MDS undergoing allo-SCT. Therefore, MRI-based LIC, and not interference-prone serum markers such as ferritin, should be preferred for pretransplant risk stratification and patient selection in future clinical trials.
Background Appropriate three-dimensional imaging of the hip joint is a substantial prerequisite for planning and performing surgical correction of deformities. Although surgeons still use computed tomography (CT), modern and fast acquisition techniques of volumetric imaging using magnetic resonance imaging (MRI) for pelvic measurements enable similar resolution. Purpose This study was designed to determine if already described measures of acetabular morphology are comparable in both techniques and if assessment can be performed with equal intra-observer and inter-observer reliability. Material and Methods Thirty-two hips (16 patients) were examined with a pelvic CT and a MRI with 3-T. Pelvic orientation was standardized by each observer in coronal, axial, and sagittal planes. Acetabular version as well as seven acetabular sector angles were measured by two observers twice with a minimum of four weeks between sessions. Results Inter-rater reliability showed excellent results for intra- and inter-rater reliability for CT (0.977-0.999) and MRI (0.969-0.998) measuring acetabular version and sector angles. Evaluating the reliability of CT and MRI for each observer revealed excellent results (0.972-0.998). Evaluating the Bland-Altman plots for intra-observer reliability showed an equal distribution of angles, within acceptable 95% limits of agreement. The same results were observed for inter-observer reliability evaluating CT and MRI as well as inter-method reliability. Conclusion Modern MRI scans are equally applicable to assess the bony pelvis as CT scans. In addition, MRI would enable the examination of soft tissues such as chondrolabral structures and muscle in the same examination. Since hip-preserving surgery is mostly conducted in younger patients, the reduction of radiation exposure is a benefit.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.