Since a comb-type rf shield was proposed in 2003 as a rf shield for future high-intensity accelerators, various types of bellow chambers and gate valves with this rf shield have been installed in the KEK B-Factory rings in series and tested with beams. Through beam tests to check the performance, a structural simplification has been tried in parallel. The temperatures of the bellow corrugations decreased by a factor of 3-6 compared to those with a conventional finger-type rf shield in most cases. The temperatures of the body of the gate valves also decreased by a factor of 2-5. These results demonstrated the availability of the comb-type rf shield. Although a discharge was observed in one simplified model, the latest model has shown no problem up to a stored beam current of 1.8 A (1.3 mA/bunch, 6 mm bunch length). Experiences with the comb-type rf shield in these four-year beam tests are reviewed here.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.