The IPAQ instruments have acceptable measurement properties, at least as good as other established self-reports. Considering the diverse samples in this study, IPAQ has reasonable measurement properties for monitoring population levels of physical activity among 18- to 65-yr-old adults in diverse settings. The short IPAQ form "last 7 d recall" is recommended for national monitoring and the long form for research requiring more detailed assessment.
Accelerometer outputs from AG and GA seem comparable when attached to the same body location in adults, whereas inconsistent differences are apparent between the two brands and placements in children, hence limiting the comparability between brands in this age group.
Accelerometers are a feasible and accurate instrument for use in large epidemiological studies of children's activity. Boys tend to be more active than girls, and there is a marked reduction in activity over the adolescent years. The great majority of younger children achieve current physical activity recommendations, whereas fewer older children do so-especially older girls.
IntroductionHuman body acceleration is often used as an indicator of daily physical activity in epidemiological research. Raw acceleration signals contain three basic components: movement, gravity, and noise. Separation of these becomes increasingly difficult during rotational movements. We aimed to evaluate five different methods (metrics) of processing acceleration signals on their ability to remove the gravitational component of acceleration during standardised mechanical movements and the implications for human daily physical activity assessment.MethodsAn industrial robot rotated accelerometers in the vertical plane. Radius, frequency, and angular range of motion were systematically varied. Three metrics (Euclidian norm minus one [ENMO], Euclidian norm of the high-pass filtered signals [HFEN], and HFEN plus Euclidean norm of low-pass filtered signals minus 1 g [HFEN+]) were derived for each experimental condition and compared against the reference acceleration (forward kinematics) of the robot arm. We then compared metrics derived from human acceleration signals from the wrist and hip in 97 adults (22–65 yr), and wrist in 63 women (20–35 yr) in whom daily activity-related energy expenditure (PAEE) was available.ResultsIn the robot experiment, HFEN+ had lowest error during (vertical plane) rotations at an oscillating frequency higher than the filter cut-off frequency while for lower frequencies ENMO performed better. In the human experiments, metrics HFEN and ENMO on hip were most discrepant (within- and between-individual explained variance of 0.90 and 0.46, respectively). ENMO, HFEN and HFEN+ explained 34%, 30% and 36% of the variance in daily PAEE, respectively, compared to 26% for a metric which did not attempt to remove the gravitational component (metric EN).ConclusionIn conclusion, none of the metrics as evaluated systematically outperformed all other metrics across a wide range of standardised kinematic conditions. However, choice of metric explains different degrees of variance in daily human physical activity.
Accurate quantification of physical activity energy expenditure is a key part of the effort to understand disorders of energy metabolism. The Actiheart, a combined heart rate (HR) and movement sensor, is designed to assess physical activity in populations. Objective: To examine aspects of Actiheart reliability and validity in mechanical settings and during walking and running. Methods: In eight Actiheart units, technical reliability (coefficients of variation, CV) and validity for movement were assessed with sinusoid accelerations (0.1-20 m/s 2 ) and for HR by simulated R-wave impulses (25-250 bpm). Agreement between Actiheart and ECG was determined during rest and treadmill locomotion (3.2-12.1 km/h). Walking and running intensity (in J/ min/kg) was assessed with indirect calorimetry in 11 men and nine women (26-50 y, 20-29 kg/m 2 ) and modelled from movement, HR, and movement þ HR by multiple linear regression, adjusting for sex. Results: Median intrainstrument CV was 0.5 and 0.03% for movement and HR, respectively. Corresponding interinstrument CV values were 5.7 and 0.03% with some evidence of heteroscedasticity for movement. The linear relationship between movement and acceleration was strong (R 2 ¼ 0.99, Po0.001). Simulated R-waves were detected within 1 bpm from 30 to 250 bpm. The 95% limits of agreement between Actiheart and ECG were À4.2 to 4.3 bpm. Correlations with intensity were generally high (R 2 40.84, Po0.001) but significantly highest when combining HR and movement (SEEo1 MET). Conclusions: The Actiheart is technically reliable and valid. Walking and running intensity may be estimated accurately but further studies are needed to assess validity in other activities and during free-living. Sponsorship: The study received financial support from the Wellcome Trust and SB was supported by a scholarship from Unilever, UK.
The combination of heart rate (HR) monitoring and movement registration may improve measurement precision of physical activity energy expenditure (PAEE). Previous attempts have used either regression methods, which do not take full advantage of synchronized data, or have not used movement data quantitatively. The objective of the study was to assess the precision of branched model estimates of PAEE by utilizing either individual calibration (IC) of HR and accelerometry or corresponding mean group calibration (GC) equations. In 12 men (20.6-25.2 kg/m2), IC and GC equations for physical activity intensity (PAI) were derived during treadmill walking and running for both HR (Polar) and hipacceleration [Computer Science and Applications (CSA)]. HR and CSA were recorded minute by minute during 22 h of whole body calorimetry and converted into PAI in four different weightings (P1-4) of the HR vs. the CSA (1-P1-4) relationships: if CSA > x, we used the P1 weighting if HR > y, otherwise P2. Similarly, if CSA < or = x, we used P3 if HR > z, otherwise P4. PAEE was calculated for a 12.5-h nonsleeping period as the time integral of PAI. A priori, we assumed P1 = 1, P2 = P3 = 0.5, P4 = 0, x = 5 counts/min, y = walking/running transition HR, and z = flex HR. These parameters were also estimated post hoc. Means +/- SD estimation errors of a priori models were -4.4 +/- 29 and 3.5 +/- 20% for IC and GC, respectively. Corresponding post hoc model errors were -1.5 +/- 13 and 0.1 +/- 9.8%, respectively. All branched models had lower errors (P < or = 0.035) than single-measure estimates of CSA (less than or equal to -45%) and HR (> or =39%), as well as their nonbranched combination (> or =25.7%). In conclusion, combining HR and CSA by branched modeling improves estimates of PAEE. IC may be less crucial with this modeling technique.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.