The Energy Performance Certificate (EPC) allows building users to be informed and aware of the quality of the buildings in terms of energy needs. Additionally, the EPC includes a future for existing buildings, which is the incorporation of a Recommendation list of Measures (RLMs) to improve their energy performance in a cost-effective way. Which have risen the question if this tool can provide trustful Cost-effective recommendations due despite the uses of standardized inputs. This study focuses on estimating the impact of using measure ventilation rate, heating set point and airtightness on the profitability of the recommendations. The study is based on common dwelling in Norway, comparing results obtained with a Building Performance Simulation Software, following the Norwegian standard for energy certification and with the uses of measured ventilation rate, airtightness and real heating set points. The results show that the performance gap can be reduced significantly just by adopting these inputs, increasing the confidence on the RLMs and reducing the uncertainty of the investment.
Phase change material (PCM) is an attractive solution for improvement of thermal performance in buildings, and have excited a vast amount of research in recent years. There are however practical challenges with ensuring adequate phase transitions of the PCM to exploit the passive heat storage benefits. Night ventilation (NV) with free cooling have surfaced as one of the most promising methods to properly utilize PCMs and maximize energy savings. This work deals with a novel spackling compound enhanced with microencapsulated PCM. The product is intended for use at inner walls and ceiling surfaces of buildings and is suited for new and retrofitting building applications. Ensuing former experimental studies, a validated simulation model is developed and used to study the PCM with natural and hybrid NV strategies in an office building during summer conditions in Oslo, Norway. Cooling load reduction and energy savings are analyzed with varying air flow rates of 0.5–5 air changes per hour (ACH) and 2–4 mm PCM layer thickness. It is shown how increasing air flow rates and PCM thickness greatly enhances energy performance, but at a diminishing rate. Although the NV alone can reduce the cooling load by 11.5% at 1 ACH, 40.2% at 3 ACH and 59.8% at 5 ACH, one can achieve further reduction up to 19.5%, 78.2% and 95.5% for the respective ACHs with 4 mm PCM. The natural NV provides more energy savings compared to the hybrid strategy. As energy requirement by fans increases with the increase of air flow rates in the hybrid strategy, the energy savings eventually start to reduce. The hybrid strategy can save 38% energy at most with 3 ACH, and the savings is increased to 50% with the inclusion of 4 mm PCM. On the other hand, the natural strategy saves 56% of energy at the same air flow rate, and 69% with 4 mm of PCM.
The Energy Performance Certificate (EPC) allows building users to be informed and aware of the quality of the buildings in terms of energy needs. Additionally, the EPC includes a future for existing buildings, which is the incorporation of a Recommendation list of Measures (RLMs) to improve their energy performance in a cost-effective way. This has risen the question if this tool can provide trustful cost-effective recommendations due despite the use of standardized inputs. This study focuses on estimating the impact of using measured ventilation rate, heating set point and airtightness on the profitability of the recommendations. The study is based on a common dwelling in Norway, comparing results obtained with a Building Performance Simulation Software, following the Norwegian standard for energy certification and with the use of measured ventilation rate, airtightness and real heating set points. The results show that the performance gap can be reduced significantly just by adopting these inputs, increasing the confidence on the RLMs and reducing the uncertainty of the investment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.