Background This prospective multicenter study funded by the DEGUM assesses the diagnostic accuracy of standardized contrast-enhanced ultrasound (CEUS) for the noninvasive diagnosis of hepatocellular carcinoma (HCC) in high-risk patients. Methods Patients at high risk for HCC with a histologically proven focal liver lesion on B-mode ultrasound were recruited prospectively in a multicenter approach. Clinical and imaging data were entered via online entry forms. The diagnostic accuracies for the noninvasive diagnosis of HCC were compared for the conventional interpretation of standardized CEUS at the time of the examination (= CEUS on-site) and the two CEUS algorithms ESCULAP (Erlanger Synopsis for Contrast-enhanced Ultrasound for Liver lesion Assessment in Patients at risk) and CEUS LI-RADS (Contrast-Enhanced UltraSound Liver Imaging Reporting and Data System). Results 321 patients were recruited in 43 centers; 299 (93.1 %) had liver cirrhosis. The diagnosis according to histology was HCC in 256 cases, and intrahepatic cholangiocarcinoma (iCCA) in 23 cases. In the subgroup of cirrhotic patients (n = 299), the highest sensitivity for the diagnosis of HCC was achieved with the CEUS algorithm ESCULAP (94.2 %) and CEUS on-site (90.9 %). The lowest sensitivity was reached with the CEUS LI-RADS algorithm (64 %; p < 0.001). However, the specificity of CEUS LI-RADS (78.9 %) was superior to that of ESCULAP (50.9 %) and CEUS on-site (64.9 %; p < 0.001). At the same time, the negative predictive value (NPV) of CEUS LI-RADS was significantly inferior to that of ESCULAP (34.1 % vs. 67.4 %; p < 0.001) and CEUS on-site (62.7 %; p < 0.001). The positive predictive values of all modalities were high (around 90 %), with the best results seen for CEUS LI-RADS and CEUS on-site. Conclusion This is the first multicenter, prospective comparison of standardized CEUS and the recently developed CEUS-based algorithms in histologically proven liver lesions in cirrhotic patients. Our results reaffirm the excellent diagnostic accuracy of CEUS for the noninvasive diagnosis of HCC in high-risk patients. However, on-site diagnosis by an experienced examiner achieves an almost equal diagnostic accuracy compared to CEUS-based diagnostic algorithms.
Purpose The purpose of this study was to analyze imaging findings in hepatic epithelioid hemangioendothelioma (HEHE) with a particular focus on contrast-enhanced ultrasound (CEUS). Materials and Methods This retrospective multicenter study included 10 patients with histologically proven HEHE from 5 European centers. All existing ultrasound images/videos were independently analyzed by 2 experienced examiners (DEGUM level III, internal medicine) using a standardized evaluation form. Patterns of contrast enhancement were correlated with computed tomography (CT), magnetic resonance imaging (MRI), and pathological findings. Results B-mode ultrasound, CEUS, CT, and MRI were performed in 90 %, 70 %, 100 %, and 90 % of patients, respectively. Multifocal HEHE could be observed in 80 % with affection of both liver lobes in 70 %. Analysis of CEUS revealed 3 characteristic patterns that correlated well with contrast patterns on CT and MRI: (a) peripheral nodular enhancement with centripetal fill-in and wash-out in the portal venous and late venous phase (PVLP), (b) rim-like arterial enhancement with wash-out in the PVLP, and (c) inversed target sign with/without wash-out in the PVLP. Wash-out in the PVLP as a sign suspicious of malignancy was observed in 6/7 patients (85.7 %). Conclusions Knowledge of the different characteristic CEUS patterns is of importance to avoid misdiagnosis due to resemblance of patterns A and B to the much more common focal liver lesions hemangioma and intrahepatic cholangiocarcinoma. Of importance, sonographers should be aware that wash-out in the PVLP might be absent in some patients.
Purpose The aim of the current study was to evaluate point of care ultrasound (POCUS) in geriatric patients by echoscopy using a handheld ultrasound device (HHUSD, VScan) at bedside in comparison to a high-end ultrasound system (HEUS) as the gold standard. Materials and Methods Prospective observational study with a total of 112 geriatric patients. The ultrasound examinations were independently performed by two experienced blinded examiners with a portable handheld device and a high-end ultrasound device. The findings were compared with respect to diagnostic findings and therapeutic implications. Results The main indications for the ultrasound examinations were dyspnea (44.6 %), fall (frailty) (24.1 %) and fever (21.4 %). The most frequently found diagnoses were cystic lesions 32.1 % (35/109), hepatic vein congestion 19.3 % (21/109) and ascites 13.6 % (15/110). HHUSD delivered 13 false-negative findings in the abdomen resulting in an “overall sensitivity” of 89.5 %. The respective “overall specificity” was 99.6 % (7 false-positive diagnoses). HHUSD (versus HEUS data) resulted in 13.6 % (17.3 %) diagnostically relevant procedures in the abdomen and 0.9 % (0.9 %) in the thorax. Without HHUSD (HEUS) 95.7 % (100 %) of important pathological findings would have been missed. Conclusion The small HHUSD tool improves clinical decision-making in immobile geriatric patients at the point of care (geriatric ward). In most cases, HHUSD allows sufficiently accurate yes/no diagnoses already at the bedside, thereby clarifying the leading symptoms for early clinical decision-making.
Purpose This study was conducted to evaluate the role of liver sonography in patients with coronavirus disease 2019 (COVID-19) and elevated liver enzymes. Materials and methods In this retrospective study, patients tested positive for SARS-CoV-2 in our emergency ward between January 01 and April 24, 2020 and elevated liver enzymes were included (Cohort 1). Additionally, the local radiology information system was screened for sonographies in COVID-19 patients at the intensive care unit in the same period (Cohort 2). Liver sonographies and histologic specimen were reviewed and suspicious findings recorded. Medical records were reviewed for clinical data. Ultrasound findings and clinical data were correlated with severity of liver enzyme elevation. Results Cohort 1: 126 patients were evaluated, of which 47 (37.3%) had elevated liver enzymes. Severity of liver enzyme elevation was associated with death (p<0.001). 8 patients (6.3%) had suspicious ultrasound findings, including signs of acute hepatitis (n = 5, e.g. thickening of gall bladder wall, hepatomegaly, decreased echogenicity of liver parenchyma) and vascular complications (n = 4). Cohort 2: 39 patients were evaluated, of which 14 are also included in Cohort 1. 19 patients (48.7%) had suspicious ultrasound findings, of which 13 patients had signs of acute hepatitis and 6 had vascular complications. Pathology was performed in 6 patients. Predominant findings were severe cholestasis and macrophage activation. Conclusion For most hospitalized COVID-19 patients, elevated liver enzymes cause little concern as they are only mild to moderate. However, in severely ill patients bedside sonography is a powerful tool to reveal different patterns of vascular, cholestatic or inflammatory complications in the liver, which are associated with high mortality. In addition, macrophage activation as histopathologic correlate for a hyperinflammatory syndrome seems to be a frequent complication in COVID-19.
Induced overexpression of the secretory protein YKL-40 promotes tumor growth in xenograft experiments. We investigated if targeting YKL-40 with a monoclonal antibody could inhibit tumor growth. YKL-40 expressing human melanoma cells (LOX) were injected subcutenously in Balb/c scid mice. Animals were treated with intraperitoneal injections of anti-YKL-40, isoptype control or PBS. Non-YKL-40 expressing human pancreatic carcinoma cell line PaCa 5061 served as additional control. MR imaging was used for evaluation of tumor growth. Two days after the first injections of anti-YKL-40, tumor volume had increased significantly compared with controls, whereas no effects were observed for control tumors from PaCa 5061 cells lacking YKL-40 expression. After 18 days, mean tumor size of the mice receiving repeated anti-YKL-40 injections was 1.82 g, >4 times higher than mean tumor size of the controls (0.42 g). The effect of anti-YKL-40 on the increase of tumor volume started within hours after injection and was dose dependent. Intratumoral hemorrhage was observed in the treated animals. The strong effect on tumor size indicates important roles for YKL-40 in melanoma growth and argues for a careful evaluation of antibody therapy directed against YKL-40.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.