Continuous imaging with 320-row area detector CT is useful to evaluate morphological changes in the esophagogastric junction area in both normal individuals and patients with reflux esophagitis.
We evaluated clinical images to investigate the usefulness of adaptive iterative dose reduction algorithm (AIDR) in the field of acute cerebral infarction. We did receiver operating characteristic (ROC) analysis by 4 radiologists using 50 clinical images (abnormal case=24, normal case=26) which were reconstructed by AIDR and filtered back projection (FBP). The area under the curve (AUC) value from average ROC curve of observers were 0.79 with the FBP and 0.87 with the AIDR (P=0.31). The standard deviation of AUC was 0.06 with the FBP and 0.03 with the AIDR. More in detail, the AUC value of Expert group (over 10 years of experience) increased to 0.06 by using AIDR compared with FBP method. On the other hand, in Beginner group (less than 10 years of experience) there was 0.09 increase. Therefore, there was some possibility to reduce the variation of diagnostic accuracy among observer and the diagnostic accuracy improvement of the doctor in a few Experience group, by using AIDR for acute cerebral infarction computed tomography (CT) examination.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.