The aim of this study is to evaluate the first results of the atlantoaxial fixation using polyaxial screw-rod system. Twenty-eight patients followed-up 12-29 months (average 17.1 months) were included in this study. The average age was 59.5 years (range 23-89 years). The atlantoaxial fusion was employed in 20 patients for an acute injury to the upper cervical spine, in 1 patient with rheumatoid arthritis for atlantoaxial vertical instability, in 1 patient for C1-C2 osteoarthritis, in 2 patients for malunion of the fractured dens. Temporary fixation was applied in two patients for type III displaced fractures of the dens and in two patients for the atlantoaxial rotatory dislocation. Retrospectively, we evaluated operative time, intraoperative bleeding and the interval of X-ray exposure. The resulting condition was subjectively evaluated by patients. We evaluated also the placement, direction and length of the screws. Fusion or stability in the temporary fixation was evaluated on radiographs taken at 3, 6, 12 weeks and 6 and 12 months after the surgery. As concerns complications, intraoperatively we monitored injury of the nerve structures and the vertebral artery. Monitoring of postoperative complications was focused on delayed healing of the wound, breaking or loosening of screws and development of malunion. Operative time ranged from 35 to 155 min, (average 83 min). Intraoperative blood loss ranged from 50 to 1,500 ml (average 540 ml). The image intensifier was used for a period of 24 s to 2 min 36 s (average 1 min 6 s). Within the postoperative evaluation, four patients complained of paresthesia in the region innervated by the greater occipital nerve. A total of 56 screws were inserted into C1, their length ranged from 26 to 34 mm (average, 30.8 mm). All screws were positioned correctly in the C1 lateral mass. Another 56 screws were inserted into C2. Their length ranged from 28 to 36 mm (average 31.4 mm). Three screws were malpositioned: one screw perforated the spinal canal and two screws protruded into the vertebral artery canal. C1-C2 stability was achieved in all patients 12 weeks after the surgery. No clinically manifested injury of the vertebral artery or nerve structures was observed in any of these cases. As for postoperative complications, we recorded wound dehiscence in one patient. The Harms C1-C2 fixation is a very effective method of stabilizing the atlantoaxial complex. The possibility of a temporary fixation without damage to the atlantoaxial joints and of reduction after the screws and rods had been inserted is quite unique.
Dynamic cervical plate designs provide less implant complications (no patient) compared with rigid plate designs (4 patients). Speed of fusion was faster in the presence of a dynamic plate. However, loss of segmental lordosis is significantly higher if dynamic plates are used, which did not result in differences regarding clinical outcome between dynamic and constrained plates after 2 years. Thus, dynamic plates should be considered to be the preferred treatment option because of the lower risk for implant failure-related revision surgery.
Anterior cervical plate fixation is an approved surgical technique for cervical spine stabilization in the presence of anterior cervical instability. Rigid plate design with screws rigidly locked to the plate is widely used and is thought to provide a better fixation for the treated spinal segment than a dynamic design in which the screws may slide when the graft is settling. Recent biomechanical studies showed that dynamic anterior plates provide a better graft loading possibly leading to accelerated spinal fusion with a lower incidence of implant complications. This, however, was investigated in vitro and does not necessarily mean to be the case in vivo, as well. Thus, the two major aspects of this study were to compare the speed of bone fusion and the rate of implant complications using either rigid-or dynamic plates. The study design is prospective, randomized, controlled, and multi-centric, having been approved by respective ethic committees of all participating sites. One hundred and thirty-two patients were included in this study and randomly assigned to one of the two groups, both undergoing routine level-1-or level-2 anterior cervical discectomy with autograft fusion receiving either a dynamic plate with screws being locked in ap -position (ABC, Aesculap, Germany), or a rigid plate (CSLP, Synthes, Switzerland). Segmental mobility and implant complications were compared after 3-and 6 months, respectively. All measurements were performed by an independent radiologist. Mobility results after 6 months were available for 77 patients (43 ABC/34 CSLP). Mean segmental mobility for the ABC group was 1.7 mm at the time of discharge, 1.4 mm after 3 months, and 0.8 mm after 6 months. For the CSLPgroup the measurements were 1.0, 1.8, and 1.7 mm, respectively. The differences of mean segmental mobility were statistically significant between both groups after 6 months (P = 0.02). Four patients of the CSLP-group demonstrated surgical hardware complications, whereas no implant complications were observed within the ABC-group (P = 0.0375). Dynamic plate designs provided a faster fusion of the cervical spine compared with rigid plate designs after prior spinal surgery. Moreover, the rate of implant complications was lower within the group of patients receiving a dynamic plate. These interim results refer to a follow-up period of 6 months after prior spinal surgery. Further investigations will be performed 2 years postoperatively.
Preservation of bilateral vertebral arteries and all cervical nerve roots is feasible when carrying out intralesional total spondylectomy in patients with C2 vertebral body tumors and should be considered in patients thought to benefit from total C2 vertebra excision. In an attempt to augment construct stability and provide anterior column load sharing, we have used mesh cage and iliac crest graft between C1 and C3 held in place with a short cervical plate without complications.
Study DesignModern biomaterials and instrumentation have popularised surgery of the thoraco-lumbar spine through an anterior route. The advantage of anterior surgery is that it allows for a direct decompression of the compromised spinal canal. However, the potential for devastating long-term sequelae as a result of complications is high.PurposeThe aim of this study was to give a general overview and identify the incidence of vascular complications.Overview of LiteratureThere is limited literature describing the overall incidence and complications of anterior spinal surgery.MethodsA retrospective review of a prospective database of 1,262 consecutive patients with anterior surgery over a twelve-year period.ResultsIn our study, 1.58% (n=20) of patients suffered complications. Injury to a major vessel was encountered in 14 (1.11%) cases, of which nine involved an injury to the common iliac vein. In six cases, the original procedure was abandoned due to a life-threatening vascular injury (n=3) and unfavourable anatomy (n=3).ConclusionsThe incidence of vascular and other complications in our study was relatively low. Nevertheless, the potential for devastating long-term sequelae as a result of complications remains high. A thorough knowledge and awareness of normal and abnormal anatomy should be gained before attempting such a procedure, and a vascular surgical assistance especially should be readily accessible. We believe use of access surgeons is mandatory in cases with difficult or aberrant anatomy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.