ObjectivesTo assess to which extent the COVID-19 pandemic affected corneal transplantation by virtue of donor selection algorithms in different European countries.DesignSurvey.Setting110 eye banks in 26 European countries.Participants64 eye banks covering 95% of European corneal transplantation activity.InterventionsA questionnaire listing the number of corneas procured and distributed from February to May 2018–2020 was circulated to eye banks.Main outcome measuresThe primary outcome was the number of corneal procurements. Additional outcomes were national algorithms for donor selection, classified according to their stringency (donors with COVID-19 history, suspected for COVID-19, asymptomatic, PCR testing) and the pandemic severity in each country. We calculated Spearman’s correlation coefficient to determine, two by two, the relationship between the 3-month decline in eye banking activity (procurement), the stringency of donor selection algorithm and the grading of pandemic severity (cases and deaths). A partial correlation was run to determine the relationship between decline and stringency while controlling for pandemic severity.ResultsProcurements decreased by 38%, 68% and 41%, respectively, in March, April and May 2020 compared with the mean of the previous 2 years, while grafts decreased, respectively, by 28%, 68% and 56% corresponding to 3866 untreated patients in 3 months. Significant disparities between countries and the decrease in activity correlated with stringency in donor selection independent of pandemic severity.ConclusionsOur data demonstrate significant differences between countries regarding donor screening algorithms based on precautionary principles and, consequently, a decrease in the donor pool, already constrained by a long list of contraindications. Fundamental studies are needed to determine the risk of SARS-CoV-2 transmission by corneal transplantation and guide evidence-based recommendations for donor selection to justify their substantial medical and economic impact.
Background The risk of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) transmission through corneal graft is an ongoing debate and leads to strict restrictions in corneas procurement, leading to a major decrease in eye banking activity. The aims of this study are to specifically assess the capacity of human cornea to be infected by SARS-CoV-2 and promote its replication ex vivo, and to evaluate the real-life risk of corneal contamination by detecting SARS-CoV-2 RNA in corneas retrieved in donors diagnosed with Coronavirus Disease 2019 (COVID-19) and nonaffected donors. Methods and findings To assess the capacity of human cornea to be infected by SARS-CoV-2, the expression pattern of SARS-CoV-2 receptor angiotensin-converting enzyme 2 (ACE-2) and activators TMPRSS2 and Cathepsins B and L in ocular surface tissues from nonaffected donors was explored by immunohistochemistry (n = 10 corneas, 78 ± 11 years, 40% female) and qPCR (n = 5 corneas, 80 ± 12 years, 40% female). Additionally, 5 freshly excised corneas (80 ± 12 years, 40% female) were infected ex vivo with highly concentrated SARS-CoV-2 solution (106 median tissue culture infectious dose (TCID50)/mL). Viral RNA was extracted from tissues and culture media and quantified by reverse transcription quantitative PCR (RT-qPCR) (viral RNA copies) 30 minutes (H0) and 24 hours (H24) after infection. To assess the risk of corneal contamination by SARS-CoV-2, viral RNA was tested by RT-qPCR (Ct value) in both corneas and organ culture media from 14 donors diagnosed with COVID-19 (74 ± 10 years, 29% female) and 26 healthy donors (79 ± 13 years, 57% female), and in organ culture media only from 133 consecutive nonaffected donors from 2 eye banks (73 ± 13 years, 29% female). The expression of receptor and activators was variable among samples at both protein and mRNA level. Based on immunohistochemistry findings, ACE-2 was localized mainly in the most superficial epithelial cells of peripheral cornea, limbus, and conjunctiva, whereas TMPRSS2 was mostly expressed in all layers of bulbar conjunctiva. A significant increase in total and positive strands of IP4 RNA sequence (RdRp viral gene) was observed from 30 minutes to 24 hours postinfection in central cornea (1.1 × 108 [95% CI: 6.4 × 107 to 2.4 × 108] to 3.0 × 109 [1.4 × 109 to 5.3 × 109], p = 0.0039 and 2.2 × 107 [1.4 × 107 to 3.6 × 107] to 5.1 × 107 [2.9 × 107 to 7.5 × 107], p = 0.0117, respectively) and in corneoscleral rim (4.5 × 109 [2.7 × 109 to 9.6 × 109] to 3.9 × 1010 [2.6 × 1010 to 4.4 × 1010], p = 0.0039 and 3.1 × 108 [1.2 × 108 to 5.3 × 108] to 7.8 × 108 [3.9 × 108 to 9.9 × 108], p = 0.0391, respectively). Viral RNA copies in ex vivo corneas were highly variable from one donor to another. Finally, viral RNA was detected in 3 out of 28 corneas (11%) from donors diagnosed with COVID-19. All samples from the 159 nonaffected donors were negative for SARS-CoV-2 RNA. The main limitation of this study relates to the limited sample size, due to limited access to donors diagnosed with COVID-19 and concomitant decrease in the procurement corneas from nonaffected donors. Conclusions In this study, we observed the expression of SARS-CoV-2 receptors and activators at the human ocular surface and a variable increase in viral RNA copies 24 hours after experimental infection of freshly excised human corneas. We also found viral RNA only in a very limited percentage of donors with positive nasopharyngeal PCR. The low rate of positivity in donors diagnosed with COVID-19 calls into question the utility of donor selection algorithms. Trial registration Agence de la Biomédecine, PFS-20-011 https://www.agence-biomedecine.fr/.
Background/aimRejection is the main cause of graft failure after penetrating keratoplasty (PK). Its prevention by repeated instillation of steroid eye-drops has not evolved in decades. Poor adherence and discontinuous nature of eye-drop treatment may explain some PK failures. In a rabbit model, we previously demonstrated that a subconjunctival dexamethasone implant was well tolerated and prevented rejection efficiently in the first 5–6 weeks. This clinical trial investigates its tolerance and safety after PK.MethodsSingle-centre, phase II non-randomised tolerance and safety pilot study (NCT02834260). Designed to analyse the risk of elevated intraocular pressure (IOP), discomfort and resorption time. Fourteen patients with a low rejection risk indication of PK were enrolled between January 2017 and August 2018. The implant was injected in the 12 o’clock position, 5 mm from the limbus, at the end of PK. A steroid eye-drop treatment was planned when implant resorption was complete. Patients were monitored regularly for 12 months: IOP (main outcome measure at 1 month), discomfort and redness scores, implant status, rejection episode and central corneal thickness by optical coherence tomography. An independent data safety monitoring committee verified safety aspects.ResultsNo increase in IOP or other adverse event related to the implant was observed. Average resorption time was 6 weeks. The switch to steroid eye-drops was uneventful. One patient, included despite preoperative corneal neovascularisation (unintended protocol deviation) experienced a rejection.ConclusionsThis is the first proof of concept that dropless immunosuppression is possible after low rejection risk PK.Trial registration numberNCT02834260.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.