The chimney technique for aortic arch pathologies is safe and feasible and may be an option in patients considered at high risk for surgery or who are ineligible for conventional TEVAR, especially in the emergency setting. Concern persists regarding type I endoleak, and long-term follow-up remains mandatory.
Within the PERICLES registry, use of nitinol/polyester stent graft devices with BECS during chimney endovascular aneurysm repair is associated with improved survival compared with other aortic endografts. However, this advantage was not observed for non-BECS repairs. Repairs incorporating multiple chimney subtypes were also associated with increased mortality risk. Importantly, increasing chimney stent number and bare-metal endolining stents increase chimney occlusion risk, whereas patients treated at low-volume centers have higher risk of type IA endoleak.
This analysis demonstrates that ch-EVAR is associated with a relatively low rate of cerebrovascular events. However, a postoperative stroke is associated with increased mortality. Ruptured aneurysms, bilateral upper extremity access as in case of multiple chimney graft placement, and longer operative times were identified as independent risk factors for MACCE.
CAS is a valid method for treating carotid artery disease, with very low rates of major adverse events and neurologic complications. The Carotid Wallstent seems to have excellent results, even with complex plaque morphology, and a low incidence of restenosis at follow-up.
Objective: The goal of this study was to present open surgical conversion with graft salvage or "semiconversion" as a definitive and safe treatment for untreatable and persistent type II endoleaks causing sac enlargement after endovascular aneurysm repair. Methods: Between January 2001 and December 2014, 25 of 1623 endovascular aortic repair (EVAR) patients were selected as candidates for open semiconversion. The indication was persistent type II endoleak in 13 patients (12 of whom received previous attempts of embolization), type I and II endoleak in 2 patients, and sac growth without imaging evidence of endoleak in the other 10. After the infrarenal aorta was prepared (via a retroperitoneal access, whenever possible), the technique consisted of performing a banding of the neck with Teflon (DuPont, Wilmington, Del), a sacotomy to remove the thrombus or the hygroma, or both, and then suturing all of the feeding vessels that were found. Proximal and distal fenestrations were performed to avoid sac repressurization. Results: The semiconversion was performed after a mean of 74 months after the initial EVAR. The mean aneurysm size at the time of the EVAR was 6.0 cm (range, 5.0-9.5 cm), and the mean aneurysm size at the time of the semiconversion was 7.7 cm (range, 5.5-11.5 cm). The overall aneurysm size increase was 38%, and the average growth rate was 8.2% per year. One patient had a stable aneurysm size but was treated because of an emergency condition. Technical success was 100%, with resolution of the endoleak and no perioperative deaths. Four cardiac deaths were registered at 12, 26, 30, and 60 months (mean follow-up, 42 months; range, 1-80 months). Conclusions: Graft salvage appears to be a valid option compared with open repair when considering treatment of persistent type II endoleak. This case series shows that semiconversion is a safe and effective treatment for otherwise untreatable type II endoleak. (J Vasc Surg 2015;62:1437-41.)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.