SummaryBackground/ObjectiveActivity is increasingly being recognized as a highly relevant parameter in all areas of healthcare for diagnosis, treatment, or outcome assessment, especially in orthopaedics where the movement apparatus is directly affected. Therefore, the aim of this study was to develop, describe, and clinically validate a generic activity-monitoring algorithm, satisfying a combination of three criteria. The algorithm must be able to identify, count, and time a large set of relevant daily activities. It must be validated for orthopaedic patients as well as healthy individuals, and the validation must be in a setting that mimics free-living conditions.MethodsUsing various technical solutions, such as a dual-axis approach, dynamic inclinometry (hip flexion), and semiautomatic calibration (gait speed), the algorithms were designed to count and time the following postures, transfers, and activities of daily living: resting/sitting, standing, walking, ascending and descending stairs, sit–stand transitions, and cycling. In addition, the number of steps per walking bout was determined. Validation was performed with healthy individuals and patients who had undergone unilateral total joint arthroplasty, representing a wide spectrum of functional capacity. Video observation was used as the gold standard to count and time activities in a validation protocol approaching free-living conditions.ResultsIn total 992 and 390 events (activities or postures) were recorded in the healthy group and patient group, respectively. The mean error varied between 0% and 2.8% for the healthy group and between 0% and 7.5% for the patient group. The error expressed in percentage of time varied between 2.0% and 3.0% for both groups.ConclusionActivity monitoring of orthopaedic patients by counting and timing a large set of relevant daily life events is feasible in a user- and patient-friendly way and at high clinical validity using a generic three-dimensional accelerometer and algorithms based on empirical and physical methods. The algorithms performed well for healthy individuals as well as patients recovering after total joint replacement in a challenging validation set-up. With such a simple and transparent method real-life activity parameters can be collected in orthopaedic practice for diagnostics, treatments, outcome assessment, or biofeedback.
Patients undergoing total knee replacement for end stage knee osteoarthritis (OA) become increasingly younger and more demanding. Consequently, outcome assessment tools need to evolve toward objective performance-based measures. We applied a novel approach toward ambulatory biomechanical assessment of physical function using a single inertial sensor located at the pelvis to derive various motion parameters during activities of daily living. We investigated the potential of a clinically feasible battery of tests to define relevant parameters of physical function. We compared preoperative measures of end stage knee OA patients to healthy subjects. Our results show that measures of time yield the highest discriminative capacity to differentiate between groups. Additionally we found disease-dependent and task-specific alterations of movement for inertial sensor-derived motion parameters with good discriminative capacity. The inertial sensor's output quantities seem to capture another clinically relevant dimension of physical function that is supplementary to time. This study demonstrates the potential of inertial sensor-based motion analysis and provides a standardized test feasible for a routine clinical application in the longitudinal follow-up.
Background: It is important to assess physical activity objectively during daily life circumstances, to understand the association between physical activity and diseases and to determine the effectiveness of interventions. Accelerometer-based physical activity monitoring seems a promising method and could potentially capture all four FITT (i.e. Frequency, Intensity, Time, Type) components of physical activity considered by the World Health Organization (WHO).Aim: To assess the four FITT components of physical activity with an accelerometer during daily life circumstances and compare with self-reported levels of physical activity in patients with knee osteoarthritis (OA) and a healthy control group.Methods: Patients (n=30) with end-stage knee OA and age-matched healthy subjects (n=30) were measured. An ambulant tri-axial accelerometer was placed onto the lateral side of the upper leg. Physical activity was measured during four consecutive days. Using algorithm-based peak detection methods in Matlab, parameters covering the four FITT components were assessed. Self-reported physical activity was assessed using the Short questionnaire to assess health enhancing physical activity (SQUASH).Results: Knee OA patients demonstrated fewer walking bouts (154 ±79 versus 215 ±65 resp.; p=0.002), step counts (4402 ±2960 steps/day versus 6943 ±2581 steps/day; p=0.001) and sit-to-stand (STS) transfers (37 ±14 versus 44 ±12; p=0.031) compared to controls. Knee OA patients demonstrated more time sitting (65 ±15% versus 57 ±10% resp.; p=0.029), less time walking (8 ±4% versus 11 ±4% resp.; p=0.014) and lower walking cadence (87 ±11steps/min versus 99 ± 8steps/min resp.; p<0.001). Accelerometer-based parameters of physical activity were moderately-strong (Pearsons’s r= 0.28-0.49) correlated to self-reported SQUASH scores.Conclusion: A single ambulant accelerometer-based physical activity monitor feasibly captures the four FITT components of physical activity and provides more insight into the actual physical activity behavior and limitations of knee OA patients in their daily life.
Gait analysis has widely been accepted as an objective measure of function and clinical outcome. Ambulatory accelerometer-based gait analysis has emerged as a clinically more feasible alternative to optical motion capture systems but does not provide kinematic characterization to identify disease dependent mechanisms causing walking disability. This study investigated the potential of a single inertial sensor to derive frontal plane motion of the pelvis (i.e. pelvic obliquity) and help identify hip osteoarthritis (OA) related gait alterations. Patients with advanced unilateral hip OA (n=20) were compared to patients with advanced unilateral knee OA (n=20) and to a healthy control group (n=20). Kinematic characterization of frontal plane pelvic motion during gait demonstrated decreased range of motion and increased asymmetry for hip OA patients specifically.
Aims: One of the instruments in the orthopaedic surgeon’s armamentarium to face the challenges associated with periprosthetic fracture around the stem of a hip replacement is the tapered, fluted, modular, titanium (TFMT) stem. Our aim was to study its clinical and radiological outcomes. Patients and Methods: During the period 2010–2016 86 patients (55 females; median age 78.2 years; mean BMI 26.3 kg/m2; median ASA classification 2) underwent 87 revisions for a Vancouver B periprosthetic fracture using a Stryker Restoration Cone-Conical stem. Results: After a median follow-up of 2.9 years no stem had to be revised and no case of stem fracture was found. Dislocation was the most common complication and occurred in 18% of patients. Other major complications were deep infection ( n = 4), subsidence >5 mm ( n = 7), and nonunion ( n = 5). 3-month and 1-year mortality was 10% and 15% respectively and was strongly correlated with age, deep infection, and ASA classification. The median EQ-5D health state index at final follow-up was 0.78 and all patients were ambulatory. Conclusions: The complication most commonly encountered was dislocation and can likely be prevented by the use of large heads, adequate reduction and fixation of the trochanteric area and restoration of the native anatomy. Contrary to previous concerns, fracture and subsidence of these modular stems do not appear to be a significant problem in this geriatric population.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.