AIMTo compare the outcomes of endoscopic submucosal dissection (ESD) for gastric neoplasms using Clutch Cutter (ESD-C) or other knives (ESD-O).METHODSThis was a single-center retrospective study. Gastric neoplasms treated by ESD between April 2016 and October 2017 at Kitakyushu Municipal Medical Center were reviewed. Multivariate analyses and propensity score matching were used to reduce biases. Covariates included factors that might affect outcomes of ESD, including age, sex, underlying disease, anti-thrombotic drugs use, tumor location, tumor position, tumor size, tumor depth, tumor morphology, tumor histology, ulcer (scar), and operator skill. The treatment outcomes were compared among two groups. The primary outcome was ESD procedure time. Secondary outcomes were en bloc, complete, and curative resection rates, and adverse events rates including perforation and delayed bleeding.RESULTSA total of 155 patients were included in this study; 44 pairs were created by propensity score matching. Background characteristics were quite similar among two groups after matching. Procedure time was significantly shorter for ESD-C (median; 49 min) than for ESD-O (median; 88.5 min) (P < 0.01). However, there was no significant difference in treatment outcomes between ESD-C and ESD-O including en bloc resection rate (100% in both groups), complete resection rate (100% in both groups), curative resection rate (86.4% vs 88.6%, P = 0.730), delayed bleeding (2.3% vs 6.8%, P = 0.62) and perforation (0% in both groups).CONCLUSIONESD-C achieved shorter procedure time without an increase in complication risk. Therefore, ESD-C could become an effective ESD option for gastric neoplasms.
Background: Endoscopic submucosal dissection (ESD) for early gastric neoplasms is still a technically difficult and time-consuming procedure. Hybrid ESD (H-ESD) involves circumferential incision with partial submucosal dissection combined with subsequent mucosal resection by snaring, wherein the newly developed device allows us to perform H-ESD using a single device. This study aimed to determine the clinical outcomes of H-ESD compared with conventional ESD (C-ESD) for early gastric neoplasms. Methods: In this multi-center, retrospective study, using propensity score-matched analysis, we reviewed the charts of patients with early gastric neoplasms smaller than 20 mm treated with H-ESD or C-ESD at three hospitals between January 2017 and October 2018. The primary outcome was the procedure time, and the secondary outcomes were other factors, including the en bloc resection rate, complete resection rate, curative resection rate, and rate of adverse events. Results: Among 215 patients, 29 underwent H-ESD and 186 underwent C-ESD; 29 pairs were created by propensity score matching. In the H-ESD group, 82.8% of lesions met the absolute indication [mucosal lesions limited to 20-mm diameter, dominated by differentiated adenocarcinoma without ulcer (scar)] for endoscopic resection (ER). As a result, the procedure time of H-ESD was significantly shorter than that of C-ESD [20 (interquartile range, 12–27) min versus 40 (30–50) min; p < 0.001]. There was no significant difference in the secondary outcomes between the two groups. Conclusion: H-ESD contributed to reduced procedure time. Therefore, H-ESD could be an alternative endoscopic treatment for gastric neoplasms when the lesion fulfils the absolute indication for ER.
SUMMARY The Clutch Cutter was invented as a scissor-type knife for endoscopic submucosal dissection (ESD) of gastrointestinal neoplasms. ESD with the scissor-type knife (ESD-S) may be considered a technically easier procedure than ESD with non-scissor-type knives (ESD-NS). Therefore, this study aimed to compare the technical outcomes of ESD-S with those of ESD-NS for superficial esophageal cancer. This was a multicenter retrospective study. Patients with superficial esophageal cancer treated with ESD between October 2015 and March 2018 at three hospitals were retrospectively reviewed. The ESD-S group had 48 patients and the ESD-NS group had 114 patients. A propensity score matching analysis was performed to compensate for the confounding bias between both groups. Multivariate analyses and propensity score matching were used to adjust for age, sex, the tumor size, tumor location, tumor depth, degree of tumor circumference, operator level, usage of the traction method, and the sedation method. The primary outcome was the procedure time of the ESD. Secondary outcomes were the rate of en-bloc/complete resection and the rate of complications including perforation, delayed bleeding, and stricture. Propensity score matching analysis provided 36 matched pairs. Median procedure time in the ESD-S group was significantly shorter than that in the ESD-NS group (44.0 min vs. 66.5 min, P = 0.020). In addition, the treatment outcomes were similar in both groups (en-bloc resection: 100% vs. 97.2%, P = 1; complete resection: 88.9% vs. 86.1%, P = 1; curative resection: 80.6% vs. 77.8%, P = 1; perforation: 0% vs. 5.6%, P = 0.49; delayed bleeding: 0% in both groups; stricture: 2.8% vs. 8.3%, P = 0.61). ESD-S was associated with a shorter procedure time than ESD-NS, without an increase in the incidence of complications. Therefore, the scissor-type knife should be considered as an endo-knife for ESD of superficial esophageal cancers.
Background: Endoscopic submucosal dissection (ESD) is a standard treatment for tumors of the gastrointestinal tract. We developed a self-completion method of ESD using Endosaber to eliminate the need for an additional device or human assistance during the procedure. The aim of this study was to evaluate the technical feasibility and outcomes of this method in an ex vivo porcine training model. Methods: This was a pilot study, and the procedures were performed by 4 experts. Mock lesions measuring 15 mm in diameter were prepared at the posterior wall in the middle or lower esophagus obtained from domestic pigs. Each operator performed ESD on the mock lesions in 3 models. The primary outcome was ESD completion rate using the self-completion method. The secondary outcomes were procedure time, en bloc resection rate, perforation rate, and number of injections during the procedure. Results: All 12 ESDs were completed using the self-completion method. The median procedure time (interquartile range) was 483.5 (399–619.3) s (median incision time: 240.4 [168.3–332.5] s; median dissection time: 222 [182.8–257] s). En bloc resection rate was 100%. No perforation was noted during any of the procedures. The median number of injections was 10.5 (9–14.3). The procedure time decreased significantly with increase in experience (p = 0.020). Conclusions: The self-completion ESD method using one Endosaber without any assistance achieved a 100% en bloc resection rate without any perforation. The need for an additional device or assistance was successfully eliminated. This method may prove to be a simple and cost-effective ESD procedure for lesions in humans.
Stem cells for pancreatitis 425 Gastric injury and bacterial overgrowth 433 The effect of visceral fat on SMA configuration 451 Antiplatelet agents in ulcerative colitis 459 Differentiation of BMSCs into intestinal ce 466 GERDOFF ® efficacy in patients with GERD
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.