BACKGROUND AND PURPOSE:Incomplete occlusion and recanalization of large and wide-neck brain aneurysms treated by endovascular therapy remains a challenge. We present preliminary clinical and angiographic results of an experimentally optimized Surpass flow diverter for treatment of intracranial aneurysms in a prospective, multicenter, nonrandomized, single-arm study.
Endovascular treatment of intracranial aneurysms (IAs) has evolved considerably over the past decades. The technological advances have been driven by the experience that coils fail to completely exclude all IAs from the blood circulation, the need to treat the diseased parent vessel segment leading to the aneurysm formation, and expansion of endovascular therapy to treat more complex IAs. Stents were initially developed to support the placement of coils inside wide neck aneurysms. However, early work on stent-like tubular braided structure led to a more sophisticated construct that then later was coined as a flow diverter (FD) and found its way into clinical application. Although FDs were initially used to treat wide-neck large and giant internal carotid artery aneurysms only amenable to surgical trap with or without a bypass or endovascular vessel sacrifice, its use in other types of IAs and cerebrovascular pathology promptly followed. Lately, we have witnessed an explosion in the application of FDs and subsequently their modifications leading to their ubiquitous use in endovascular therapy. In this review we aim to compile the available FD technology, evaluate the devices’ peculiarities from the authors’ perspective, and analyze the current literature to support initial and expanded indications, recognizing that this may be outdated soon.
BackgroundWide necked bifurcation aneurysms (WNBA) are among the most difficult aneurysms to treat. Very low dome-to-neck (DTN) and aspect ratios provide an even greater challenge in the management of WNBAs. We present the safety and efficacy profile for endovascular clip system (eCLIPs) device in the treatment of this subset of WNBAs with very unfavorable morphologies.MethodsIn our case series, 24 patients treated at 12 international centers were taken from a larger prospective voluntary post-marketing registry of 65 patients treated with the eCLIPs device and coiling. Those who had WNBAs at either the carotid or basilar terminus with a DTN ratio <1.6 and aspect ratio <1.2 were included. Radiologic and clinical outcomes were assessed immediately after the procedure and at the latest follow-up.ResultsThe eCLIPs device was successfully deployed in 23 cases (96%). One patient (4.2%) died due to guidewire perforation distal to the implant site. No other complications were documented. After a mean follow-up of 15.8 months (range 3–40 months), good radiologic outcomes (modified Raymond–Roy classification (MRRC) scores of 1 or 2) were documented in 20 of 21 patients (95%) with follow-up data. The lone patient with an MRRC score of 3 showed coiled compaction after incomplete neck coverage with the device.ConclusionOur series of patients with aneurysms having adverse DTN and aspect ratios demonstrated that the eCLIPs device has a safety and efficacy profile comparable with currently available devices in the treatment of WNBAs.
Introduction Carotid cavernous fistulas (CCFs) are rare, usually follow head trauma or aneurysmal rupture. Recent treatment options include endovascular techniques such as flow diversion devices (FDDs). Objective To present our case treated with FDD application with transarterial cavernous-sinus coiling and present a systematic review on the use and effectiveness of FDDs in CCF treatment. Materials and methods We present our case of CCF treatment with FDD. A search was also conducted in PubMed, EMBASE and Cochrane until November 2020. Reference lists were also cross-checked. Results Including our case, thirty-eight patients were identified with a CCF that was treated with FDDs in sixteen studies. Twenty-two patients were females, nine were males and the rest unidentified. The mean age was 52,6 years (range 17–86, SD± 19.28). Thirty-six patients suffered from direct and two from indirect CCFs. Single FDD was used in four cases, single FDD with embolic materials in eleven cases, multiple overlapping FDDs were used in six cases and multiple overlapping FDDs with embolic materials were used in seventeen cases. Thirty-five patients (92,1%) had clinical improvement, immediate angiographic occlusion was seen in 44,7% of the cases, while long-term occlusion rate was 100% but with variable follow-up periods. One patient (2,6%) presented with a neurological deficit related to FDD deployment. Conclusion Targeted treatment of CCFs with single or overlapping FDDs with or without adjunct embolic agents offers a high success rate, both clinically and long-term angiographically compared to other endovascular methods alone. However, further research with multi-center prospective trials is warranted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.