An apparatus for measuring the conversion efficiency η and several further key properties of thermoelectric generators is presented. To achieve highest reliability and accuracy the crucial determination of the thermal energy that is supplied to the generator is done by an absolute method, i.e. by measuring the electrical power that is dissipated in a thermally guarded resistive heater. The accuracy of this method was carefully verified with a traceable calibration standard. The data evaluation is discussed for test measurements of a high efficiency Bi2Te3 module and compared to results that are estimated from the material properties. Excellent accuracy, consistency and reproducibility of the data are found, which makes the measurement a sensitive and reliable tool for the development of thermoelectric generators.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.