It is hypothesized that ilio-sacro-iliacal corridors for a new envisioned pelvic ring implant (trans-sacral nail with two iliacal bolts ¼ ISI-nail: ilio-sacro-iliacal nail) exists on the level of S1-or S2-vertebra in each patient. The corridors of 84 healthy human pelves (42x <; 42x ,, 18-85 years) were measured in high resolution CT scans using the Merlin Diagnostic Workcenter Software. Trans-sacral corridors (!9 mm diameter) on the level of S1 and S2 were found in 62% and 54% of pelves with a mean length [mm AE SD] of 164 AE 12.9 and 142 AE 10.2. Corresponding iliac corridors were present in all specimens in caudally tilted axial planes of 37.8 AE 0.67å nd 53.7 AE 0.94˚in relation to the operating table plane and divergent angulations of 69.0 AE 0.49˚and 70.1 AE 0.32˚in relation to the sagittal midline plane. Sacral dysmorphism, with compensatory larger S2 corridors were prevalent in 24% of pelves; ilio-sacro-iliacal osseous corridors for the envisioned implant were found in 88% of pelves on the level of S1 or S2. In the remaining 12% with too narrow corridors for any trans-sacral implant (screws, bars, ISI nail) alternative fixation methods have to be considered. Expected advantages of the envisioned ISI nail compared to available fixation devices are discussed. ß
Background:Volar locking plate fixation has become the gold standard in the treatment of unstable distal radius fractures. Juxta-articular screws should be placed as close as possible to the subchondral zone, in an optimized length to buttress the articular surface and address the contralateral cortical bone. On the other hand, intra-articular screw misplacements will promote osteoarthritis, while the penetration of the contralateral bone surface may result in tendon irritations and ruptures. The intraoperative control of fracture reduction and implant positioning is limited in the common postero-anterior and true lateral two-dimensional (2D)-fluoroscopic views. Therefore, additional 2D-fluoroscopic views in different projections and intraoperative three-dimensional (3D) fluoroscopy were recently reported. Nevertheless, their utility has issued controversies.Objectives:The following questions should be answered in this study; 1) Are the additional tangential view and the intraoperative 3D fluoroscopy useful in the clinical routine to detect persistent fracture dislocations and screw misplacements, to prevent revision surgery? 2) Which is the most dangerous plate hole for screw misplacement?Patients and Methods:A total of 48 patients (36 females and 13 males) with 49 unstable distal radius fractures (22 x 23 A; 2 x 23 B, and 25 x 23 C) were treated with a 2.4 mm variable angle LCP Two-Column volar distal radius plate (Synthes GmbH, Oberdorf, Switzerland) during a 10-month period. After final fixation, according to the manufactures' technique guide and control of implant placement in the two common perpendicular 2D-fluoroscopic images (postero-anterior and true lateral), an additional tangential view and intraoperative 3D fluoroscopic scan were performed to control the anatomic fracture reduction and screw placements. Intraoperative revision rates due to screw misplacements (intra-articular or overlength) were evaluated. Additionally, the number of surgeons, time and radiation-exposure, for each step of the operating procedure, were recorded.Results:In the standard 2D-fluoroscopic views (postero-anterior and true lateral projection), 22 screw misplacements of 232 inserted screws were not detected. Based on the additional tangential view, 12 screws were exchanged, followed by further 10 screws after performing the 3D fluoroscopic scan. The most lateral screw position had the highest risk for screw misplacement (accounting for 45.5% of all exchanged screws). The mean number of images for the tangential view was 3 ± 2.5 images. The mean surgical time was extended by 10.02 ± 3.82 minutes for the 3D fluoroscopic scan. An additional radiation exposure of 4.4 ± 4.5seconds, with a dose area product of 39.2 ± 14.5 cGy/cm2 were necessary for the tangential view and 54.4 ± 20.9 seconds with a dose area product of 2.1 ± 2.2 cGy/cm2, for the 3D fluoroscopic scan.Conclusions:We recommend the additional 2D-fluoroscopic tangential view for detection of screw misplacements caused by overlength, with penetration on the dorsal cortic...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.