Step counting has long been used as a method of measuring distance. Starting in the mid-1900s, researchers became interested in using steps per day to quantify ambulatory physical activity. This line of research gained momentum after 1995, with the introduction of reasonably accurate spring-levered pedometers with digital displays. Since 2010, the use of accelerometer-based “activity trackers” by private citizens has skyrocketed. Steps have several advantages as a metric for assessing physical activity: they are intuitive, easy to measure, objective, and they represent a fundamental unit of human ambulatory activity. However, since they measure a human behavior, they have inherent biological variability; this means that measurements must be made over 3–7 days to attain valid and reliable estimates. There are many different kinds of step counters, designed to be worn on various sites on the body; all of these devices have strengths and limitations. In cross-sectional studies, strong associations between steps per day and health variables have been documented. Currently, at least eight prospective, longitudinal studies using accelerometers are being conducted that may help to establish dose–response relationships between steps/day and health outcomes. Longitudinal interventions using step counters have shown that they can help inactive individuals to increase by 2500 steps per day. Step counting is useful for surveillance, and studies have been conducted in a number of countries around the world. Future challenges include the need to establish testing protocols and accuracy standards, and to decide upon the best placement sites. These challenges should be addressed in order to achieve harmonization between studies, and to accurately quantify dose–response relationships.
PurposeThe purpose of this study was to assess the accuracy of the Cosmed K5 portable metabolic system dynamic mixing chamber (MC) and breath-by-breath (BxB) modes against the criterion Douglas bag (DB) method.MethodsFifteen participants (mean age±SD, 30.6±7.4 yrs) had their metabolic variables measured at rest and during cycling at 50, 100, 150, 200, and 250W. During each stage, participants were connected to the first respiratory gas collection method (randomized) for the first four minutes to reach steady state, followed by 3-min (or 5-min for DB) collection periods for the resting condition, and 2-min collection periods for all cycling intensities. Collection periods for the second and third methods were preceded by a washout of 1–3 min. Repeated measures ANOVAs were used to compare metabolic variables measured by each method, for seated rest and each cycling work rate.ResultsFor ventilation (VE) and oxygen uptake (VO2), the K5 MC and BxB modes were within 2.1 l/min (VE) and 0.08 l/min (VO2) of the DB (p≥0.05). Compared to DB values, carbon dioxide production (VCO2) was significantly underestimated by the K5 BxB mode at work rates ≥150W by 0.12–0.31 l/min (p<0.05). K5 MC and BxB respiratory exchange ratio values were significantly lower than DB at cycling work rates ≥100W by 0.03–0.08 (p<0.05).ConclusionCompared to the DB method, the K5 MC and BxB modes are acceptable for measuring VE and VO2 across a wide range of cycling intensities. Both K5 modes provided comparable values to each other.
Unsupervised semantic segmentation in the time series domain is a much studied problem due to its potential to detect unexpected regularities and regimes in poorly understood data. However, the current techniques have several shortcomings, which have limited the adoption of time series semantic segmentation beyond academic settings for four primary reasons. First, most methods require setting/learning many parameters and thus may have problems generalizing to novel situations. Second, most methods implicitly assume that all the data is segmentable and have difficulty when that assumption is unwarranted. Thirdly, many algorithms are only defined for the single dimensional case, despite the ubiquity of multi-dimensional data. Finally, most research efforts have been confined to the batch case, but online segmentation is clearly more useful and actionable. To address these issues, we present a multi-dimensional algorithm, which is domain agnostic, has only one, easily-determined parameter, and can handle data streaming at a high rate. In this context, we test the algorithm on the largest and most diverse collection of time series datasets ever considered for this task and demonstrate the algorithm’s superiority over current solutions.
The combined use of gyroscope and accelerometer at the hip and ankles improved individual-level prediction of EE compared with accelerometer only. For the wrists, adding gyroscope produced negligible changes. The magnetometer did not meaningfully improve estimates for any algorithms.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.