BackgroundTo evaluate the risks and benefits of endoscopic submucosal dissection (ESD) in addition to chemoradiotherapy (CRT) for the treatment of superficial esophageal squamous cell carcinoma (SESCC).Methods and materialsWe retrospectively reviewed the treatment outcomes of 47 patients with SESCC treated between October 2000 and December 2011. Sixteen patients with invasion into the submucosal layer (T1b) or the muscularis mucosa (m3) with positive vascular invasion were treated with CRT after ESD (ESD-CRT group). The lymph node area was irradiated to a total dose of 40–44 Gy and a boost radiation was administered if PET-positive lymph nodes or positive margins were observed. The remaining 31 patients received definitive CRT only (dCRT group).ResultsThe radiation field was significantly larger in the ESD-CRT group; the “long T” was used in 11 patients (35.4%) in the dCRT group and 15 (93.7%) in the ESD-CRT group (p = 0.0001). The total radiation dose was smaller in the ESD-CRT group; 40 Gy was used in 10 patients (62.5%) in the ESD-CRT group and all but one patient in the dCRT group received ≥60 Gy (p = 0.00001). The 3-year overall survival rates in the dCRT and ESD-CRT groups were 63.2% and 90.0% respectively (p = 0.118). Recurrence developed in nine patients (29.0%) in the dCRT group and one (6.3%) in the ESD-CRT group. Local recurrence was observed in six patients (19%) in the dCRT group and none in the ESD-CRT-group (p = 0.029). Pericardial effusion (≥Grade 3) occurred in three patients (9.7%) in the dCRT group and none in the ESD-CRT group.ConclusionsESD followed by CRT is an effective and safe approach for SESCC at m3 or T1b. This combination of ESD and CRT improves the local control rate, and it could decrease the number of cardiac toxicities due to a radiation-dose reduction relative to CRT alone.
Purpose
We sought to develop machine learning models to detect multileaf collimator (MLC) modeling errors with the use of radiomic features of fluence maps measured in patient‐specific quality assurance (QA) for intensity‐modulated radiation therapy (IMRT) with an electric portal imaging device (EPID).
Methods
Fluence maps measured with EPID for 38 beams from 19 clinical IMRT plans were assessed. Plans with various degrees of error in MLC modeling parameters [i.e., MLC transmission factor (TF) and dosimetric leaf gap (DLG)] and plans with an MLC positional error for comparison were created. For a total of 152 error plans for each type of error, we calculated fluence difference maps for each beam by subtracting the calculated maps from the measured maps. A total of 837 radiomic features were extracted from each fluence difference map, and we determined the number of features used for the training dataset in the machine learning models by using random forest regression. Machine learning models using the five typical algorithms [decision tree, k‐nearest neighbor (kNN), support vector machine (SVM), logistic regression, and random forest] for binary classification between the error‐free plan and the plan with the corresponding error for each type of error were developed. We used part of the total dataset to perform fourfold cross‐validation to tune the models, and we used the remaining test dataset to evaluate the performance of the developed models. A gamma analysis was also performed between the measured and calculated fluence maps with the criteria of 3%/2 and 2%/2 mm for all of the types of error.
Results
The radiomic features and its optimal number were similar for the models for the TF and the DLG error detection, which was different from the MLC positional error. The highest sensitivity was obtained as 0.913 for the TF error with SVM and logistic regression, 0.978 for the DLG error with kNN and SVM, and 1.000 for the MLC positional error with kNN, SVM, and random forest. The highest specificity was obtained as 1.000 for the TF error with a decision tree, SVM, and logistic regression, 1.000 for the DLG error with a decision tree, logistic regression, and random forest, and 0.909 for the MLC positional error with a decision tree and logistic regression. The gamma analysis showed the poorest performance in which sensitivities were 0.737 for the TF error and the DLG error and 0.882 for the MLC positional error for 3%/2 mm. The addition of another type of error to fluence maps significantly reduced the sensitivity for the TF and the DLG error, whereas no effect was observed for the MLC positional error detection.
Conclusions
Compared to the conventional gamma analysis, the radiomics‐based machine learning models showed higher sensitivity and specificity in detecting a single type of the MLC modeling error and the MLC positional error. Although the developed models need further improvement for detecting multiple types of error, radiomics‐based IMRT QA was shown to be a promising approach for detecting the MLC modeli...
ESD represents an acceptable treatment option for recurrent or residual ESCC because of its improvement in local control, when local failure after CRT is limited to the submucosal layer without metastases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.