, Melissa Yssel, MB ChB, FC Path(SA) Chem 139, and Wendy M. Zakowicz, BS 79 Purpose: To achieve clinical validation of cutoff values for newborn screening by tandem mass spectrometry through a worldwide collaborative effort. Methods: Cumulative percentiles of amino acids and acylcarnitines in dried blood spots of approximately 25-30 million normal newborns and 10,742 deidentified true positive cases are compared to assign clinical significance, which is achieved when the median of a disorder range is, and usually markedly outside, either the 99th or the 1st percentile of the normal population. The cutoff target ranges of analytes and ratios are then defined as the interval between selected percentiles of the two populations. When overlaps occur, adjustments are made to maximize sensitivity and specificity taking all available factors into consideration.
Purpose: To improve quality of newborn screening by tandem mass spectrometry with a novel approach made possible by the collaboration of 154 laboratories in 49 countries. Methods: A database of 767,464 results from 12,721 cases affected with 60 conditions was used to build multivariate pattern recognition software that generates tools integrating multiple clinically significant results into a single score. This score is determined by the overlap between normal and disease ranges, penetration within the disease range, differences between conditions, and weighted correction factors. Results: Ninety tools target either a single condition or the differential diagnosis between multiple conditions. Scores are expressed as the percentile rank among all cases with the same condition and are compared to interpretation guidelines. Retrospective evaluation of past cases suggests that these tools could have avoided at least half of 279 false-positive outcomes caused by carrier status for fatty-acid oxidation disorders and could have prevented 88% of known false-negative events. Conclusions: Application of this computational approach to raw data is independent from single analyte cutoff values. In Minnesota, the tools have been a major contributing factor to the sustained achievement of a false-positive rate below 0.1% and a positive predictive value above 60%
It has been proposed that neonatal thyroid-stimulating hormone (TSH) concentrations are a good indicator of iodine deficiency in the population. A frequency of neonatal TSH concentrations above 5 mU/L below 3% has been proposed as the threshold indicating iodine sufficiency. The objective of the present study was to evaluate feasibility and usefulness of nation-wide neonatal TSH concentration screening results to assess iodine status in Belgium. All newborns born in Belgium during the period 2009–2011 (n = 377713) were included in the study, except those suffering from congenital hypothyroidism and premature neonates. The frequency of neonatal TSH concentrations above 5 mU/L from 2009 to 2011 in Belgium fluctuated between 2.6 and 3.3% in the centres using the same TSH assay. There was a significant inverse association between neonatal TSH level and birth weight. The longer the duration between birth and screening, the lower the TSH level. Neonatal TSH levels were significantly lower in winter than in spring or autumn and significantly lower in spring and summer than in autumn while significantly higher in spring compared to summer. In conclusion, despite that pregnant women in Belgium are mildly iodine deficient, the frequency of neonatal TSH concentrations above 5 mU/L was very low, suggesting that the neonatal TSH threshold proposed for detecting iodine deficiency needs to be re-evaluated. Although neonatal TSH is useful to detect severe iodine deficiency, it should not be recommended presently for the evaluation of iodine status in mildly iodine deficient regions.
Phenylketonuria is a metabolic disease caused by phenylalanine hydroxylase deficiency. Treatment is based on a strict natural protein-restricted diet that is associated with the risk of malnutrition and severe psychosocial burden. Oral administration of tetrahydrobiopterin can increase residual enzyme activity, but most patients with severe clinical phenotypes are nonresponders. We performed liver cell transplantation in a 6-year-old boy with severe tetrahydrobiopterin nonresponsive phenylketonuria who failed to comply with diet prescriptions. The transplanted hepatocytes were obtained in part from an explanted glycogen storage type 1b liver. Following two infusions, blood phenylalanine levels returned within the therapeutic target while the phenylalanine half-life assessed by loading tests decreased from 43 to 19 h. However, 3 months later, blood phenylalanine concentrations increased and the phenylalanine intake had to be reduced. Cell-based therapy is a promising therapeutic option in phenylketonuria, and the domino concept may solve the issue of cell sources for hepatocyte transplantation.
Background: Neonatal screening programs for sickle cell disease are now widespread in North American and European countries. Most programs apply isoelectric focusing or HPLC to detect hemoglobin variants. Because tandem mass spectrometry (MS/MS) is being used for screening of inherited metabolic disorders and allows protein identification, it was worth testing for hemoglobinopathy screening. Methods: We minimized sample preparation and analysis times by avoiding prior purification, derivatization, or separation. We developed a tryptic digestion methodology to screen for the main clinically important variants (Hb S, Hb C, and Hb E) and β-thalassemia. To ensure proper discrimination between homozygote and heterozygote variants, we selected 4 transitions with good signal intensities for each specific peptide and calculated variant/Hb A ratios for each. Method validation included intra- and interseries variability, carryover, and limit of detection. We also performed a comparative study with isoelectric focusing results on 2082 specimens. Results: Intraassay imprecision values (CVs) varied between 2.5% and 30.7%. Interassay CVs were between 6.3% and 23.6%. Carryover was <0.03%, and the limit of detection was fixed at 1% of Hb S. According to the MS/MS settings (detection of Hb S, Hb C, Hb E, and β-globin production defects), the comparative study did not yield any discrepant results between the 2 techniques. Conclusions: MS/MS is a reliable method for hemoglobinopathy neonatal screening.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.