The side-to-side difference found in maximal heel-rise height can be explained by a difference in Achilles tendon length in patients recovering from an Achilles tendon rupture. Minimizing tendon elongation appears to be an important treatment goal when aiming for full return of function.
Background: Total hip arthroplasty (THA) is traditionally associated with a low complication rate, with complications such as infection, fracture and dislocation requiring readmission or reoperation. We seek to identify the complication rate among the anterior, direct lateral and posterior surgical approaches. Methods: We reviewed all THAs performed at the Epworth Healthcare from 1 July 2014 to 30 June 2016. There were 2437 THAs performed by a variety of approaches. No hips were excluded from this study. We surveyed the hospital database and the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) to identify those patients who had been readmitted and/or reoperated on. Details collected included age, gender, laterality of the surgery (left/right/bilateral), surgical approach utilised, complications which occurred. Results: There were 29 peri-prosthetic fractures detected (13 anterior, 9 lateral, 7 posterior) and 10 underwent revision of implant, 19 were fixed. The increased rate of revision in the anterior group was statistically significant. There were 14 dislocations (5 anterior, 1 lateral, 8 posterior) of which 8 prostheses were revised. Three cases operated via the anterior approach and 1 by the lateral had early subsidence without fracture, necessitating revision of the femoral prostheses. Operative site infection occurred in 12 cases (2 anterior, 4 lateral, 6 posterior) with 6 requiring revision of implants. Conclusion: The complication rates between the 3 main approaches are similar, but individual surgeons should be vigilant for complications unique to their surgical approaches, such as femoral fractures in the anterior approach and dislocations in the posterior approach.
Mega-aneurysms of saphenous vein grafts (SVGs) to coronary arteries are rare complications of bypass surgery. We report the development of superior vena cava syndrome secondary to an SVG mega-aneurysm with concomitant fistulous communication to the right atrium. Successful treatment was achieved by coil embolization and chronic anticoagulation.
Positron emission tomography with`50-labeled water (H2150) can be used to delineate abnormal regional myocardial blood flow in experimental animals. To determine the feasibility of this method in humans, we studied 33 subjects (9 normal volunteers and 24 patients with angiographically documented coronary artery disease) at rest and after myocardial hyperemia induced with intravenous infusion of dipyridamole. At rest, the myocardial region demonstrating the lowest relative H2`50 activity exhibited 71 + 8% of activity in the region with peak activity in control subjects and 62 + 17% in patients (p = NS). After the dipyridamole infusion, differences between the two groups were accentuated. In control subjects, activity in the region with lowest relative radioactivity averaged 77 5% of that in the region with peak activity. In patients, it averaged 55 ±+22% of activity in the region with peak activity (p<0.01). Results in patients with ischemia with or without a history of remote myocardial infarction were not significantly different. In 22 of the 24 patients, the region with lowest relative perfusion corresponded anatomically to the region of myocardium distal to a stenosis. Thus, delineation of regional myocardial perfusion in patients with coronary artery disease is possible with positron emission tomography and H215O. Further studies will be necessary to prospectively determine sensitivity and specificity. (Circulation 1988;78:612- Received July 27, 1987; revision accepted May 5, 1988.`3 N-labeled ammonia2-4 and 52Rb5-7 have been successfully used to estimate regional myocardial blood flow in experimental animals and in patients. 82Rb is particularly attractive in the clinical setting because it is generator produced, which obviates the need for an on-site cyclotron. However, the use of these tracers for quantification of flow entails some limitations. Single-pass extraction and myocardial retention of`3N-labeled ammonia are influenced by flow23,8 as well as by cell membrane integrity9 and the metabolic state of the myocardium.8 9 Extraction of 82Rb also varies with flow and metabolism. 5,6,10 An ideal perfusion tracer should be either freely diffusible or completely extractable and retainable by myocardium on a single pass through the coronary circulation without having its kinetics altered throughout the range of flow studied or by the metabolic status of the myocardium. 150-labeled water (H2`50) is essentially a freely diffusible tracer in the heart with uptake that does not vary despite wide variations in flow rate11 or changes in the metabolic state of myocardium associated with prolonged ischemia or reperfusion. 11-14 150 is a useful
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.