Advanced material development, including at the nanoscale, comprises costly and complex challenges coupled to ensuring human and environmental safety. Governmental agencies regulating safety have announced interest toward acceptance of safety data generated under the collective term New Approach Methodologies (NAMs), as such technologies/approaches offer marked potential to progress the integration of safety testing measures during innovation from idea to product launch of nanomaterials. Divided in overall eight main categories, searchable databases for grouping and read across purposes, exposure assessment and modeling, in silico modeling of physicochemical structure and hazard data, in vitro high‐throughput and high‐content screening assays, dose‐response assessments and modeling, analyses of biological processes and toxicity pathways, kinetics and dose extrapolation, consideration of relevant exposure levels and biomarker endpoints typify such useful NAMs. Their application generally agrees with articulated stakeholder needs for improvement of safety testing procedures. They further fit for inclusion and add value in nanomaterials risk assessment tools. Overall 37 of 50 evaluated NAMs and tiered workflows applying NAMs are recommended for considering safer‐by‐design innovation, including guidance to the selection of specific NAMs in the eight categories. An innovation funnel enriched with safety methods is ultimately proposed under the central aim of promoting rigorous nanomaterials innovation.
The ECETOC TRA model (presently version 3.1) is often used to estimate worker inhalation and dermal exposure in regulatory risk assessment. The dermal model in ECETOC TRA has not yet been validated by comparison with independent measured exposure levels. This was the goal of the present study. Measured exposure levels and relevant contextual information were gathered via literature search, websites of relevant occupational health institutes and direct requests for data to industry. Exposure data were clustered in so-called exposure cases, which are sets of data from one data source that are expected to have the same values for input parameters in the ECETOC TRA dermal exposure model. For each exposure case, the 75th percentile of measured values was calculated, because the model intends to estimate these values. The input values for the parameters in ECETOC TRA were assigned by an expert elicitation and consensus building process, based on descriptions of relevant contextual information.From more than 35 data sources, 106 useful exposure cases were derived, that were used for direct comparison with the model estimates. The exposure cases covered a large part of the ECETOC TRA dermal exposure model. The model explained 37% of the variance in the 75th percentiles of measured values. In around 80% of the exposure cases, the model estimate was higher than the 75th percentile of measured values. In the remaining exposure cases, the model estimate may not be sufficiently conservative.The model was shown to have a clear bias towards (severe) overestimation of dermal exposure at low measured exposure values, while all cases of apparent underestimation by the ECETOC TRA dermal exposure model occurred at high measured exposure values. This can be partly explained by a built-in bias in the effect of concentration of substance in product used, duration of exposure and the use of protective gloves in the model. The effect of protective gloves was calculated to be on average a factor of 34 in this data set, while factors of five to ten were used in the model estimations. There was also an effect of the sampling method in the measured data on the exposure levels. Exposure cases where sampling was done via an interception method, such as gloves, on average showed a factor of six higher 75th percentiles of measured values than exposure cases where sampling was done via a removal method, such as hand washing. This may partly be responsible for the apparent underestimation of dermal exposure by the model at high exposure values. However, there also appeared to be a relation between expected exposure level (as indicated by the model estimate) and the choice of sampling method.In this study, solid substances used in liquid products were treated as liquids with negligible volatility. The results indicate that the ECETOC TRA dermal exposure model performs equally well for these substances as for liquids. There were suggestions of a difference in performance of the model between solids and liquids.For several parts of the ECETOC TRA der...
The aim of this study was to (a) develop a method for converting particle number concentrations (PNC) obtained by Dylos to PM2.5 mass concentrations, (b) compare this conversion with similar methods available in the literature, and (c) compare Dylos PM2.5 obtained using all available conversion methods with gravimetric samples. Data were collected in multiple residences in three European countries using the Dylos and an Aerodynamic Particle Sizer (APS, TSI) in the Netherlands or an optical particle counter (OPC, GRIMM) in Greece. Two statistical fitted curves were developed based on Dylos PNC and either an APS or an OPC particle mass concentrations (PMC). In addition, at the homes of 16 volunteers (UK and Netherlands), Dylos measurements were collected along with gravimetric samples. The Dylos PNC were transformed to PMC using all the fitted curves obtained during this study (and three found in the literature) and were compared with gravimetric samples. The method developed in the present study using an OPC showed the highest correlation (Pearson (R) = 0.63, Concordance (ρc) = 0.61) with gravimetric data. The other methods resulted in an underestimation of PMC compared to gravimetric measurements (R = 0.65‐0.55, ρc = 0.51‐0.24). In conclusion, estimation of PM2.5 concentrations using the Dylos is acceptable for indicative purposes.
There is a principal need for more precise methodology with regard to the determination of occupational dermal exposure. The goal of the Systematic analysis of Dermal Exposure to hazardous chemical Agents at the workplace project was therefore to generate scientific knowledge to improve and standardize measurement methods for dermal exposure to chemicals at the workplace. In addition, the comparability of different measurement methods was investigated. Different methods (body sampling by means of coveralls and patches, hand sampling by means of gloves and washing, and head sampling by means of headbands and wiping) were compared. Volunteers repeatedly performed a selection of tasks under standardized conditions in test chambers to increase the reproducibility and decrease variability. The selected tasks were pouring, rolling, spraying, and handling of objects immersed in liquid formulations, as well as dumping and handling objects contaminated with powder. For the chemical analysis, the surrogate test substance Tinopal SWN was analyzed by means of a high-performance liquid chromatographic method using a fluorescence detector. Tinopal SWN was either applied as a solid product in its pure form, or as a low and high viscosity liquid containing Tinopal SWN in dissolved form. To compare the sampling methods with patches and coveralls, the exposure values as measured on the patches were extrapolated to the surface areas of the respective parts of the coverall. Based on this extrapolation approach, using the patch method resulted in somewhat higher exposure values compared to using a coverall for all exposure situations, but the differences were only statistically significant in case of the liquid exposure situations. Using gloves resulted in significantly higher exposure values compared to hand wash for handling immersed objects, rolling, and handling contaminated objects, and slightly higher (not significant) exposure values during pouring and spraying. In the same context, applying wipe sampling resulted in higher exposure values than using a headband, which was at least partly due to extrapolation of the wipe results to the surface area of the headband. No ‘golden standard’ with regard to a preferred measurement method for dermal exposure could be identified from the methods as investigated in the current study.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.