Background and Objectives: Little information is available on the role of Vitamin D as a micro-nutrient deficiency with masticatory muscle efficiency and its effect on the function of removable prosthesis. The aim of this study was to evaluate the role of vitamin D on masticatory muscle activity among completely edentulous patients and its effect on the retention of removable complete dentures (RCDs). Materials and Methods: A non-randomized clinical control trial was conducted on completely edentulous patients (60.53 ± 7.01 years) in the Indian population between 2017 and 2019. Subjects were evaluated for temporomandibular disorders according to the Diagnostic Criteria for Temporomandibular Disorders (DC/TMD). Serum Vitamin D (S Vit D) levels, Ultrasonography (USG), and surface Electromyography (sEMG) readings of the masseter muscle were recorded at enrolment (Level 0), after 3 months of Vitamin D therapy (Level 3), and after consecutive 3 months of maintenance therapy, i.e., after 6 months from baseline (Level 6). The fabrication of new RCDs was done for all after the enrolment, and the retention of RCDs was assessed by asking a question regarding denture retention and asking respondents to mark their satisfaction on a 5-point Likert scale. Data were analysed using ANOVA, Paired’-test and Pearson correlation coefficients. A p-value less than 0.05 indicated a statistically significant association. Results: Between enrolment and a six-month follow-up, S Vit D levels showed an increase from 16.03 ± 5.68 ng/mL to 31.35 ± 9.28 ng/mL, showing an increase of 15.32 ± 9.38 ng/mL (95.57% rise). Statistically significant values were observed for USG and sEMG. Conclusions: Results showed that S Vit D affects masticatory muscle activity by improving its thickness and boosting its tonicity. Healthy muscles assist in the retention of RCDs, consequently aiding in mastication, speech, and phonetics, hence improving patient satisfaction. Clinical implication: Acknowledging the fact that the prevalence of Vitamin D deficiency is worldwide. We suggest Vitamin D therapy as a nutritional intervention among the elderly completely edentulous population, following dietary counselling, and consider Vitamin D therapy to be an adjunct to nutritional counselling for improving masticatory muscle activity and efficiency, which aids in RCD retention and stability. Consequently, improving oral health-related quality of life for individuals.
Artificial intelligence (AI) is a contemporary, information-driven innovative technology. Prosthetic dentistry, also known as prosthodontics, is the restoration and reconstruction of missing teeth utilizing implants for permanent and removable prostheses. It enhances healthy soft and hard tissues, promoting oral health. This study examined the use of artificial intelligence in prosthodontics to diagnose abnormalities and create patient-specific prostheses. Two researchers searched Google Scholar, Scopus, PubMed/MEDLINE, EBSCO host, Science Direct, and Web of Science (MEDLINE, WOS, and KJD). Articles on AI in English were reviewed. We also collected the following broad article aspects: research and control groups, assessment methodology, outcomes, and quality rankings. This methodological study examined AI use in prosthodontics using the latest scientific findings. The findings were statistically evaluated using ANOVA. Titles and abstracts revealed 172 AI-related dentistry studies, which were analyzed in this research. Thirty-eight papers were eliminated. According to the evaluation, AI was found to have significantly increased in prosthodontics. Despite the vast number of studies documenting AI applications, the description of the data illustrated the latest breakthroughs in AI in prosthodontics, highlighting its use in automatically produced diagnostics, predicting analytics, and classification or verification tools.
Background and objectives Polyvinyl ether siloxane (PVES) possesses ideal characteristics for making precise and accurate dental impressions. PVES dimensional stability owes to its better polymeric properties derived from its parent materials poly ethers and polyvinyl siloxanes. As recommended use of chemical disinfecting agents is getting more popular, there is a growing concern associated with the effect of disinfectants on PVES dimensional stability. This study was aimed to understand the PVES behavior when subjected to chemical disinfectants. Materials and methodology The data was collected from research studies retrieved from Google Scholar, Scopus, and PubMed using MeSH terms of keywords “vinyl polyether siloxane AND Disinfection” or (Vinyl polyether siloxane OR polyvinyl siloxane ether OR PVES) AND (disinfectant OR disinfection)” without any restriction to publication date. The PRISMA (Preferred Reporting Items for Systemic Review and Meta-Analysis) directions were observed during the data collection, screening of studies, and meta-analysis. The primary data were retrieved, and batch exported from databases using Harzing’s Publish or Perish software; primary analysis was performed in Microsoft Excel, while statistical analysis for effect size, two-tailed p-values, and heterogeneity among studies was performed using Meta Essentials. The effect size was calculated using Hedge’s g values at the 95% confidence level using the random-effects model. Heterogeneity among studies was measured using the Cochrane Q and I2. Results and conclusion Dental impressions made from the PVES elastomeric impression materials showed no significant changes in dimensional stability. Immersion in the chemical disinfectant for 10 min was associated with clinically irrelevant changes in the dimensions of the PVES impressions. Disinfection with sodium hypochlorite was associated with clinically significant changes in dimensions, with a two-tailed p-value of 0.049. Disinfection with 2–2.5% glutaraldehyde solution was not associated with any significant dimensional variability.
Aim: To evaluate and compare the clinical outcomes of Cention-N (CN) and stainless steel crowns (SSCs) as restorations for pulpotomised primary molars, and to study clinical and radiographic outcomes of pulpotomies restored with these materials. Methods: The study was conducted on 60 pulpotomised molars with occlusoproximal caries. These were randomly divided into two groups and restored with either stainless steel crowns or Cention-N. Clinical performance of restorations and clinical and radiographic success of pulpotomy was examined at 6, 9 and 12 months. Results: The mean scores for marginal integrity deteriorated significantly at 6, 9 and 12 months in both groups but in comparison were insignificant. The mean for proximal contact deteriorated significantly for the Cention-N group, whereas the mean for gingival health deteriorated remarkably for the stainless steel crown group at successive evaluations. No tooth in either group showed secondary caries or discomfort on biting, except for one tooth in Cention-N group which presented with secondary caries. The clinical success rate for pulpotomised molars was 100% for both groups until nine months, although this had reduced by the end of 12 months. Radiographically, the success rate was 79.3% for Cention-N, while it was 86.6% for stainless steel crowns at 12 months. There was no significant difference in clinical and radiographic success between either group. Conclusion: Cention-N and stainless steel crowns are comparable for marginal integrity. However, crowns maintain significantly better proximal contacts while Cention-N was notably better for gingival health of the restored tooth. Both materials do not show secondary caries and discomfort on biting and are comparable in clinical and radiographic success of pulpotomy at the end of one year.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.