EVALUATION OF THE SHEAR BOND STRENGTH OF THE UNION BETWEEN TWO CoCr-ALLOYS AND A DENTAL CERAMICNTRODUCTION: Based on the importance of the integrity of the metal/ceramic interface, the purpose of this work was to evaluate the shear bond strength of the metal-ceramic union of two Co-Cr alloys (Wirobond C, Bego; Remanium 2000, Dentaurum) combined with Omega 900 ceramic (Vita Zahnfabrik). MATERIAL and METHOD: Eleven cylindrical matrixes were made for each alloy, and the metallic portion was obtained with the lost wax casting technique with standardized waxing of 4mm of height and of 4mm of diameter. The ceramic was applied according to the manufacturer's recommendations with the aid of a teflon matrix that allowed its dimension to be standardized in the same size as the metallic portion. The specimens were submitted to the shear bond test in an universal testing machine (EMIC), with the aid of a device developed for such intention, and constant speed of 0.5mm/min. RESULTS and CONCLUSIONS: The mean resistance was 48.387MPa for Wirobond C alloy, with standard deviation of 17.718, and 55.956MPa for Remanium 2000, with standard deviation of 17.198. No statistically significant difference was observed between the shear strength of the two metal-ceramic alloys. Uniterms: Ceramics; Shear test; Alloys NTRODUÇÃO: Baseados na importância da integridade da interface metal-cerâmica, este trabalho tem como objetivo avaliar a resistência ao cisalhamento da união metal-cerâmica de duas ligas de Co-Cr (Wirobond C, Bego; Remanium 2000, Dentaurum) combinadas com a cerâmica Omega 900 (Vita Zahnfabrik). MATERIAIS E MÉTODOS: Foram confeccionados 11 corpos-de-prova cilíndricos para cada liga utilizada, sendo que a porção metálica foi obtida por fundição pela técnica da cera perdida, através de enceramentos padronizados com 4mm de altura por 4mm de diâmetro. A aplicação da cerâmica foi realizada segundo recomendações do fabricante, com auxílio de uma matriz de teflon que permitia sua padronização com as mesmas dimensões da porção metálica. Os corpos-de-prova foram submetidos ao ensaio de resistência ao cisalhamento em máquina de ensaios universal (EMIC), com auxílio de dispositivo desenvolvido para tal propósito, sob velocidade constante de 0,5mm/ min. RESULTADOS E CONCLUSÕES: As médias de resistência obtidas foram 48,387 MPa para a liga Wirobond C, com desvio padrão de 17,718, e 55,956 MPa para a Remanium 2000, com desvio padrão de 17,198. Após análise de variância foi possível observar que não há diferença estatisticamente significante entre os valores de resistência ao cisalhamento das duas ligas metalocerâmicas.
The aim of this study was to analyze the laboratorial performance of dentin-bonding agents, glass ionomer cements and compomers, regarding the sealing of the gingival margins of class V cavities, prepared on the cementoenamel junction. Standardized class V cavities (4 x 3 x 2 mm) were prepared on the buccal and lingual/palatal surfaces of 20 extracted human third molars. Forty cavities were restored with different combinations of materials, as follows: group 1 (G1)--Vitremer (3M); group 2 (G2)--Vitremer (3M) and Syntac Sprint/Tetric Ceram (Vivadent); Group 3 (G3)--Syntac Sprint/Tetric Ceram (Vivadent); Group 4 (G4)--Prime & Bond 2.1/Variglass (Dentsply). After thermocycling in methylene blue dye, the specimens were longitudinally sectioned and analyzed with a stereoscopic lens in order to evaluate the leakage on the gingival margin. The obtained data were analyzed with the Mann-Whitney test, and the results revealed significantly better sealing (p = 0.05) in G1, when compared with G4. No significant differences were seen between the other groups. Under the given conditions, Vitremer offered better sealing of the gingival margin than the system Prime & Bond 2.1/Variglass.
O conhecimento do comportamento mecânico do sistema de implante corresponde a um importante parâmetro no prognóstico de uma reabilitação protética. Objetivo: avaliar a influência do formato de tecido ósseo na distribuição de tensões no implante do tipo cone morse e tecido ósseo por meio do método dos elementos finitos tridimensionais. Materiais e método: foram utilizados três tipos de formatos de modelos para tecidos ósseos: a) paralelepípedo; b) tronco elíptico; c) gerado a partir dos dados de uma tomografia. Nos modelos tridimensionais, foram instalados implantes que receberam aplicação de duas cargas de 100 N no sentido craniocaudal: 1) na direção vertical ao longo do eixo axial e 2) na direção oblíqua a 45° do eixo axial de vestibular para lingual. Resultados: as tensões de von Mises máximas (MPa) nos modelos do implante cone morse (CM) e do tecido ósseo do tipo paralelepípedo foram de 14.30 no carregamento vertical e de 60.78 no carregamento oblíquo; no modelo de tecido ósseo elíptico, foram de 14.69 no carregamento vertical e de 71.66 no carregamento oblíquo; no modelo de tecido ósseo com a configuração originada da tomografia, foram de 15.04 no carregamento vertical e de 79.15 no carregamento oblíquo. Conclusão: o formato dos modelos de tecido ósseo influenciou no comportamento e na distribuição das tensões, sendo que o modelo gerado pelos dados da tomografia apresentou os maiores valores de tensões.
up with accuracy for the positional differences between the planned and postoperative outcomes less that 0.53 mm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.