In order to support the operation of ITER and the planned experimental programme an extensive set of plasma and first wall measurements will be required. The number and type of required measurements will be similar to those made on the present-day large tokamaks while the specification of the measurements-time and spatial resolutions, etc-will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements.The implementation of diagnostic systems on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R&D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required.The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all the plasma parameters needed to support the basic and advanced operation (including active control) of the device, machine protection and also those needed to support the physics programme. Once the requirements are defined, the appropriate (combination of) diagnostic techniques can be selected and their implementation onto the tokamak can be developed. The selected list of diagnostics is an important guideline for identifying dedicated research and development needs in the area of ITER diagnostics.This paper gives a comprehensive overview of recent progress in the field of ITER diagnostics with emphasis on the implementation issues. After a discussion of the measurement requirements for plasma parameters in ITER and their justifications, recent progress in the field of diagnostics to measure a selected set of plasma parameters is presented. The integration of the various diagnostic systems onto the ITER tokamak is described. Generic research and development in the field of irradiation effects on materials and environmental effects on first mirrors are briefly presented. The paper ends with an assessment of the measurement capability for ITER and a forward of what will be gained from operation of the various diagnostic systems on ITER in preparation for the machines that will follow ITER. Performance assessment relative to requirements Design meets requirements S339 A.J.H. Donné et alPhysics Basis [7] and remains essentially the same. However, for ITER, the specific limits have changed. 2.1.2.Measurements needed for plasma control and evaluation. The measurements needed for plasma control and evaluation are naturally directly linked to the experimental programme, and particularly to the operating phase (i.e. H, D or D/T) and the operating scenario (H-mode, hybrid, etc). Since there is expected to be a phased introduction of po...
The soft X ray diagnostic at JET views the plasma from six directions with a total of 215 lines of sight. The good coverage of the plasma makes it possible to make detailed tomographic reconstructions of the soft X ray emission during various conditions. One of the tomography methods applied at JET is discussed: a grid based constrained optimization method that uses anisotropic smoothness on flux surfaces as regularization. This method has made it possible to study in detail the transport of heavy trace impurities injected into the plasma by laser blow-off. Impurity injection experiments in hot ion H mode and optimized shear plasmas are presented and discussed. The addition of a number of features to the algorithm, notably a non-negativity constraint, has made it possible to reconstruct very localized soft X ray emission from the wall during edge localized modes (ELMs). The detectors suffer damage from the neutrons produced in deuterium-deuterium (DD) fusion reactions. This damage influences the sensitivity of the detectors, which makes it necessary to cross-calibrate the cameras. A method based on tomographic reconstructions has been developed to achieve the cross-calibration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.